نتایج جستجو برای: vascular diameter ratio

تعداد نتایج: 803170  

2005
Toyotaka Yada Osamu Hiramatsu Akihiro Kimura Masami Goto Yasuo Ogasawara Katsuhiko Tsujioka Shinji Yamamori Kohei Ohno Hidehiro Hosaka Fumihiko Kajiya

We developed a portable needle-probe videomicroscope with a charge-coupled device (CCD) camera to visualize the subendocardial microcirculation. In 12 open-chest anesthetized pigs, the sheathed needle probe with a doughnut-shaped balloon and a microtube for flushing away the intervening blood was introduced into the left ventricle through an incision in the left atrial appendage via the mitral ...

Journal: :Circulation 2004
Akihiro Hosaka Hiroyuki Koyama Toshihiro Kushibiki Yasuhiko Tabata Nobuhiro Nishiyama Tetsuro Miyata Hiroshi Shigematsu Tsuyoshi Takato Hirokazu Nagawa

BACKGROUND Various growth factors promote collateral vessel development and are regarded as promising for the treatment of vascular occlusive diseases. However, an efficacious delivery system for them has yet to be established. We devised a strategy to augment functional collateral vessels by using acidic gelatin hydrogel microspheres (AGHMs) incorporating basic fibroblast growth factor (bFGF)....

2017
Sarah McGrory Adele M Taylor Mirna Kirin Janie Corley Alison Pattie Simon R Cox Baljean Dhillon Joanna M Wardlaw Fergus N Doubal John M Starr Emanuele Trucco Thomas J MacGillivray Ian J Deary

AIM To examine the relationship between retinal vascular morphology and cognitive abilities in a narrow-age cohort of community-dwelling older people. METHODS Digital retinal images taken at age ∼73 years from 683 participants of the Lothian Birth Cohort 1936 (LBC1936) were analysed with Singapore I Vessel Assessment (SIVA) software. Multiple regression models were applied to determine cross-...

Journal: :American journal of physiology. Heart and circulatory physiology 2004
Ghada Kalsho Ghassan S Kassab

The branching pattern of the coronary arteries and veins is asymmetric, i.e., many small vessels branch off of a large trunk such that the two daughter vessels at a bifurcation are of unequal diameters and lengths. One important implication of the geometric vascular asymmetry is the dispersion of blood flow at a bifurcation, which leads to large spatial heterogeneity of myocardial blood flow. T...

Journal: :hepatitis monthly 0
mona a abu el makarem department of internal medicine, minia university, egypt +20-862366553, [email protected]; department of internal medicine, minia university, egypt +20-862366553, [email protected] mohamed e shatat department of internal medicine, minia university, egypt yehya shaker department of internal medicine, minia university, egypt ahmad a abdel aleem department of internal medicine, minia university, egypt ali m el sherif department of internal medicine, minia university, egypt maysa abdel moaty department of internal medicine, minia university, egypt

2017
Nuoxin Wang Wenfu Zheng Shiyu Cheng Wei Zhang Shaoqin Liu Xingyu Jiang

In this paper, we investigate essential mechanical properties and cell behaviors of the scaffolds fabricated by rolling polylactic-co-glycolic acid (PLGA) electrospinning (ES) films for small-diameter vascular grafts (inner diameter < 6 mm). The newly developed strategy can be used to fabricate small diameter vascular grafts with or without pre-seeded cells, which are two main branches for smal...

2018
Shuang Dou Chunyan Zheng Xiuli Ji Wei Wang Mengshuang Xie Liwei Cui Wei Xiao

Background Pulmonary vascular disease, especially pulmonary hypertension, is an important complication of COPD. Bronchiectasis is considered not only a comorbidity of COPD, but also a risk factor for vascular diseases. The main pulmonary artery to aorta diameter ratio (PA:A ratio) has been found to be a reliable indicator of pulmonary vascular disease. It is hypothesized that the co-existence o...

2017
Shuangyue Xu Fangna Lu Lianna Cheng Chenglin Li Xu Zhou Yuan Wu Hongxing Chen Kaichuang Zhang Lumin Wang Junjie Xia Guoliang Yan Zhongquan Qi

BACKGROUND The development of a suitable extracellular matrix (ECM) scaffold is the first step in vascular tissue engineering (VTE). Synthetic vascular grafts are available as an alternative to autologous vessels in large-diameter arteries (>8 mm) and medium-diameter arteries (6-8 mm). In small-diameter vessels (<6 mm), synthetic vascular grafts are of limited use due to poor patency rates. Com...

Journal: :Circulation 1992
D D Miller F J Rivera O J Garcia J C Palmaz H J Berger H F Weisman

BACKGROUND To evaluate the in vivo safety, biodistribution, and diagnostic accuracy of a monoclonal Fab' antibody (S12) that is specific for the platelet membrane glycoprotein (GMP-140) expressed during platelet activation at vascular injury sites, 11 peripheral percutaneous transluminal angioplasty (PTA) patients (age, 61 +/- 8 years) with severe vascular disease had serial 99mTcS12 radionucli...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید