نتایج جستجو برای: tidal volume tv

تعداد نتایج: 349592  

Journal: :Critical Care 2003
Nicolò Patroniti Antonio Pesenti

Recent studies have shown that application of the ARDSNet low tidal volume strategy (i.e. allowing an increase in respiratory rate in order to minimize hypercapnia in those with low tidal volume) may generate consistent auto-PEEP (positive end-expiratory pressure), and this is not efficient in improving clearance of carbon dioxide. The present commentary deals with some of the recent controvers...

2013
Brian M Fuller Nicholas M Mohr Anne M Drewry Christopher R Carpenter

INTRODUCTION The most appropriate tidal volume in patients without acute respiratory distress syndrome (ARDS) is controversial and has not been rigorously examined. Our objective was to determine whether a mechanical ventilation strategy using lower tidal volume is associated with a decreased incidence of progression to ARDS when compared with a higher tidal volume strategy. METHODS A systema...

Journal: :Archives of disease in childhood. Fetal and neonatal edition 1994
K M Bartholomew K G Brownlee S Snowden P R Dear

It is well recognised that reducing positive end expiratory pressure (PEEP) leads to an increase in the tidal volume and minute volume in ventilated neonates. The magnitude of this effect is perhaps not commonly appreciated, however. Effectively, PEEP is four times as potent as peak inflation pressure (PIP) in bringing about changes in tidal volume. The influence of changes in PEEP and PIP on t...

Journal: :British journal of anaesthesia 2014
M A Levin P J McCormick H M Lin L Hosseinian G W Fischer

BACKGROUND Anaesthetists have traditionally ventilated patients' lungs with tidal volumes (TVs) between 10 and 15 ml kg(-1) of ideal body weight (IBW), without the use of PEEP. Over the past decade, influenced by the results of the Acute Respiratory Distress Syndrome Network trial, many anaesthetists have begun using lower TVs during surgery. It is unclear whether the benefits of low TV ventila...

2015
Kaoru Sumida Noriko Sato Miho Ota Koji Sakai Yasumasa Nippashi Daichi Sone Kota Yokoyama Kimiteru Ito Norihide Maikusa Etsuko Imabayashi Hiroshi Matsuda Kei Yamada Miho Murata Akira Kunimatsu Kuni Ohtomo

PURPOSE We examined the temperature of the intraventricular cerebrospinal fluid (Tv) in patients with Parkinson's disease (PD) and those with multiple system atrophy (MSA) in comparison with healthy subjects, and we examined normal changes in this temperature with aging. METHODS Tv was estimated by magnetic resonance (MR) diffusion-weighted imaging (DWI) thermometry in 36 PD patients (19 male...

Journal: :Journal of the Franklin Institute 1891

Journal: :The European respiratory journal 2003
C M Salome C W Thorpe C Diba N J Brown N Berend G G King

After bronchoconstriction, deep inspiration (DI) causes dilatation followed by airway re-narrowing. Re-narrowing may be faster in asthmatic than nonasthmatic subjects. This study investigated the relationship between re-narrowing and the magnitude of both DI-induced dilatation and the volume-dependence of respiratory system resistance (Rrs) during tidal breathing. In 25 asthmatic and 18 nonasth...

Journal: :Clinical science 1981
P J Rees T J Clark

1. Recordings were made of the pattern of breathing during and after smoking a cigarette in 14 smokers and nine non-smokers. 2. The most consistent effect was an increase in tidal volume during smoking which reverted to baseline over 1-2 min. Changes in breath times were smaller and less consistent. Similar effects were observed with intermittent inhalations of charcoal. 3 In four subjects the ...

Journal: :Anesthesiology 2009
Demet Sulemanji Andrew Marchese Paul Garbarini Marc Wysocki Robert M Kacmarek

BACKGROUND Adaptive support ventilation (ASV) allows the clinician to set a maximum plateau pressure (PP) and automatically adjusts tidal volume to keep PP below the set maximum. METHODS ASV was compared to a fixed tidal volume of 6 ml/kg. ASV determined the respiratory rate and tidal volume based on its algorithms. Maximum airway pressure limit was 28 cm H2O in ASV. Six sets of lung mechanic...

Journal: :Journal of Thoracic Disease 2019

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید