نتایج جستجو برای: thermoluminescence dosimetry

تعداد نتایج: 8971  

2016
A. Entezam M. U. Khandaker Y. M. Amin N. M. Ung D. A. Bradley J. Maah M. J. Safari F. Moradi

Study has been made of the thermoluminescence (TL) response of silica-based Ge-doped cylindrical, flat and photonic crystal fibres (referred to herein as PCF-collapsed) to electron (6, 12 and 20 MeV) and photon (6, 10 MV) irradiation and 1.25 MeV γ-rays, for doses from 0.1 Gy to 100 Gy. The electron and photon irradiations were delivered through use of a Varian Model 2100C linear accelerator lo...

2016
M. Böhm R. Grasser A. Hofstaetter A. Scharmann M. Bohm

— In tungstate and molybdate crystals having scheelite structure various (intrinsic and extrinsic) hole and electron centres are created by X-irradiation at liquid nitrogen temperature. Several of these centres have been thoroughly investigated by electron paramagnetic resonance (EPR) measurements. Their thermal decay and optical bleaching, resp., can be related to glow peaks of thermoluminesce...

2004
K. Koike H. Chihara C. Koike M. Nakagawa M. Okada M. Matsumura J. Takada

the date of receipt and acceptance should be inserted later Abstract. Possible forsterite nanoparticle model of the Extended Red Emission(ERE) is proposed on the basis of photo-luminescence of forsterite after gamma-ray and neutron irradiation. Forsterite exhibits interesting thermoluminescence spectrum similar to ERE of Red Rectangle after irradiation in low temperature. It is shown that the f...

Journal: :Journal of physics. Condensed matter : an Institute of Physics journal 2009
N R J Poolton R H Kars J Wallinga A J J Bos

The significance and extent of band-tail states in the luminescence and dosimetry properties of natural aluminosilicates (feldspars) is investigated by means of studies using low temperature (10 K) irradiation and optically stimulated luminescence (OSL) stimulation spectroscopy, and thermoluminescence (TL) in the range 10-200 K, made in comparison with high temperature (300 K) irradiation and p...

2014
R. Chen V. Pagonis

Superlinear dose dependence of thermoluminescence (TL) and optically stimulated luminescence (OSL) has been reported for many materials. The theoretical explanation has been ascribed to competition of either traps or recombination centers, during the excitation stage or during the read-out phase. There has been an account in the literature on superlinearity of OSL associated with merely one tra...

Journal: :Clinical cancer research : an official journal of the American Association for Cancer Research 1999
M Sarfaraz B W Wessels

The purpose of this study was to validate an analytical expression for the absorbed-dose calculation from the spherical source of beta-emitting radionuclides and to apply it to micrometastases treated with radiolabeled monoclonal antibodies. The self-absorbed fractions from I-131 and P-32 uniform spherical sources were calculated using the analytical expression introduced by P. K. Leichner (J. ...

2000
Basile Spyropoulos Dimitris Batistatos Dimitris Glotsos Ioannis Marneris

Background information: Electromagnetic radiation is the transmission of energy in the form of waves having an electric and magnetic component. Almost all forms of electromagnetic radiation, which constitute the electromagnetic spectrum, such as radio waves, visible, infrared, and uliraviolet light, X-rays and gamma rays, are employed in the contemporary Hospital. There are some crucial decisio...

Journal: :Radiation protection dosimetry 2014
Y Wang Y Jiang X Chu J Xu P D Townsend

Numerous materials have been proposed for thermoluminescence dosemeter, and the example of highest sensitivity is cited as magnesium orthosilicate doped with terbium (Mg2SiO4:Tb). Nevertheless, the material is currently not commercially attractive because the sensitivity varies greatly with synthesis techniques. This is a multi-parameter problem, and the current work explores some of the condit...

Journal: :Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine 2010
Alessandro M Costa Gustavo L Barbi Edenyse C Bertucci Heberton Ferreira Simone Z Sansavino Beatriz Colenci Linda V E Caldas

The ultimate check of the actual dose delivered to a patient in radiotherapy can only be achieved by using in vivo dosimetry. This work reports a pilot study to test the applicability of a thermoluminescent dosimetric system for performing in vivo entrance dose measurements in external photon beam radiotherapy. The measurements demonstrated the value of thermoluminescent dosimetry as a treatmen...

Journal: :Radiation protection dosimetry 2004
Vasilis Pagonis Hezekiah Carty

The pre-dose technique of thermoluminescence for quartz has been used extensively for retrospective dosimetry of quartz and other natural materials. A recently published model that is a modification of the well-known Zimmerman theory is used here to simulate the complete sequence of experimental steps taken during the additive dose version of the pre-dose technique. The results of simulation sh...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید