نتایج جستجو برای: surface plasmon resonance spr

تعداد نتایج: 836457  

2017
Li Wang Xiu-Mei Wan Ran Gao Dan-Feng Lu Zhimei Qi

A wavelength-interrogated surface plasmon resonance (SPR) sensor based on a nanoporous gold (NPG) film has been fabricated for the sensitive detection of trace quantities of benzo[a]pyrene (BaP) in water. The large-area uniform NPG film was prepared by a two-step process that includes sputtering deposition of a 60-nm-thick AuAg alloy film on a glass substrate and chemical dealloying of the allo...

Journal: :Analytical chemistry 2004
Soonwoo Chah Challa V Kumar Matthew R Hammond Richard N Zare

We have made surface plasmon resonance (SPR) measurements of yeast iso-1-cytochrome c (Cyt c) on a gold surface. Angle-resolved SPR curves are recorded as a function of urea concentration before and after self-assembly of the Cyt c. Exposure to a urea solution causes denaturation of Cyt c, which shifts the minimum in the SPR curve to a larger angle and decreases the signal amplitude. The Gibbs ...

2013
Guang Li Xian Li Meng Yang Meng-Meng Chen Long-Cong Chen Xing-Liang Xiong

In this study a novel sensitive nanogold particle sensor enhancement based on mixed self-assembled monolayers was explored and used to construct a Surface Plasmon Resonance (SPR) immunosensor to detect Ischemia Modified Albumin (IMA). Compared with a direct binding SPR assay at a limit of detection (LOD) of 100 ng/L, gold nanoparticles (AuNPs) of 10 nm dramatically improved the LOD of IMA to 10...

Journal: :Optics express 2009
Sylvain Herminjard Lorenzo Sirigu Hans Peter Herzig Eric Studemann Andrea Crottini Jean-Paul Pellaux Tobias Gresch Milan Fischer Jérôme Faist

We present the first optical sensor based on Surface Plasmon Resonance (SPR) operating in the mid-infrared range. The experimental setup is based on a Kretschmann geometry with Ti/Au layers deposited on a CaF(2) prism where light excitation is provided by a Quantum Cascade Laser (QCL) source. Evidence of SPR is presented and the sensing capability of the system is demonstrated by using CO(2) an...

Journal: :The Review of scientific instruments 2012
A Serrano O Rodríguez de la Fuente V Collado J Rubio-Zuazo C Monton G R Castro M A García

We present an experimental setup for the simultaneous measurement of surface plasmon resonance (SPR) and x-ray absorption spectroscopy (XAS) on metallic thin films at a synchrotron beamline. The system allows measuring in situ and in real time the effect of x-ray irradiation on the SPR curves to explore the interaction of x-rays with matter. It is also possible to record XAS spectra while excit...

Journal: :Analytical chemistry 2007
Shaopeng Wang Erica S Forzani Nongjian Tao

High-resolution differential surface plasmon resonance (SPR) with anodic stripping voltammetry (ASV) capability has been demonstrated for detecting heavy metal ions in water. Metal ions are electroplated onto the gold SPR sensing surface and are quantitatively detected by stripping voltammetry. Both the SPR angular shift and electrochemical current signal are recorded to identify the type and a...

Journal: :Optics letters 2012
Feng Xiao Guangyuan Li Kamal Alameh Anshi Xu

A new sensing approach based on the use of an optical Fabry-Pérot (FP) cavity in conjunction with surface plasmon resonance (SPR) is proposed and theoretically investigated. The impact of the SPR on the intensity and phase response of the proposed sensor structure is evaluated using a modified FP model that takes into account the SPR effect. Compared to the conventional optical-phase-detection-...

Journal: :Biochemistry 1994
Z Salamon Y Wang M F Brown H A Macleod G Tollin

Surface plasmon resonance (SPR) spectroscopy has been used to follow incorporation and light-induced conformational changes in bovine rhodopsin reconstituted into an egg phosphatidylcholine bilayer deposited on a thin silver film. The magnitude of the SPR spectral changes caused by light varies with pH in a manner paralleling that in flash photolysis experiments, which monitor formation of meta...

2012
K. M. Byun J. W. Leem J. S. Yu

We demonstrated enhanced surface plasmon resonance (SPR) detection by incorporating an indium tin oxide (ITO) layer on a thin gold film. Porous ITO layers were fabricated by e-beam evaporation and slanted deposition at room temperature and the ITO structure was optimized in terms of the surface roughness and the SPR curve characteristics. In sensing experiments, the results obtained by ethanol–...

Journal: :journal of nanostructures 2013
m. ghorbanpour

the aim of this study is experimental assay of sensitivity and stability of a bimetallic silver/gold spr sensor chip. this chip utilizes the sensitivity of the silver and the stability of the gold. moreover, the silver layer (instead of usual cr or ti layer) was used as an adhesive intermediate layer between the gold layer and the glass substrate. the optimization of the gold/silver thickness u...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید