نتایج جستجو برای: surface nmr signal

تعداد نتایج: 1078099  

غفاریان مقرب, محمد هادی , محمودی, مرتضی, ملکوتی, محمد جعفر ,

To date, limited research has been done worldwide on uptake and translocation of nanoparticles (NPs) by plants. To evaluate such processes, soybean (Glycine max L.) was cultured in modified Hoagland nutrient solution containing Fe3O4 NPs with concentration of 60 mg/L, and 33 mg/L iron chelate (Fe-EDTA) was taken as control. After 28 days, the strength of magnetic signal was measured in differen...

Journal: :Physical review letters 2005
I M Savukov M V Romalis

We demonstrate detection of NMR signals using a noncryogenic atomic magnetometer and describe several novel applications of this technique. A nuclear spin-precession signal from water is detected using a spin-exchange-relaxation-free potassium magnetometer. We also demonstrate detection of less than 10(13) 129Xe atoms whose NMR signal is enhanced by a factor of 540 due to Fermi-contact interact...

Journal: :Journal of Chemical Physics 2021

The field of zero- to ultralow-field (ZULF) nuclear magnetic resonance (NMR) is currently experiencing a rapid growth, owing the progress in optical magnetometry, and also attractive features ZULF NMR, such as low hardware cost excellent spectral resolution achieved under conditions. In this work, an approach proposed demonstrated for simultaneous acquisition ZULF-NMR spectra individual 13C-con...

Journal: :Lab on a chip 2006
Susanna Ahola Federico Casanova Juan Perlo Kerstin Münnemann Bernhard Blümich Siegfried Stapf

The velocity distribution of liquid flowing in a commercial micromixer has been determined directly by using pulsed-field gradient NMR. Velocity maps with a spatial resolution of 29 microm x 43 microm were obtained by combining standard imaging gradient units with a homebuilt rectangular surface coil matching the mixer geometry. The technique provides access to mixers and reactors of arbitrary ...

2013
P. Andris T. Dermek I. Frollo

The paper describes a receive coil system for low-field NMR scanner intended for cardio measurements. The coil system is based on good qualities of surface coils accommodating them to volume measurements. The active volume of the coil is widened using two inductively coupled resonators. Signal from the coil system is amplified using a highimpedance preamplifier thus no special matching is neces...

2015
P. Andris I. Frollo

The paper describes studies dealing with problems of the receive coil for NMR scanner connected via a preamplifier with high input impedance. Behaviour of the coil with preamplifier after pulses of RF signal was studied and an equation was derived and verified for investigation of it. The theory is demonstrated on a one-turn surface coil with rather large dimensions. Some parameters of a coil a...

Journal: :Proceedings of the National Academy of Sciences of the United States of America 1988
T Jue D L Rothman J A Lohman E W Hughes C C Hanstock R G Shulman

By incorporating the hyperbolic secant inversion pulses with the image-selected in vivo spectroscopy localization technique and by applying a gradient-echo imaging method, we have selected only the 31P NMR signals from orthotopic human kidney and liver, using a single concentric 1H/31P surface coil. Corresponding to the experimental results on animal studies, the phosphocreatine signal is drama...

Journal: :Organic & biomolecular chemistry 2013
Xiaoyan Zhang Haiyang Zhao Xianliang Cao Ningmei Feng Demei Tian Haibing Li

The recognition of the mercury(II) ion (Hg(2+)) is essential because of its extreme toxicity in the environment and food. Hence we reported a novel cysteine (Cys) complex of piperidine-calix[4]arene (L) as a convenient and effective dual-signal responsive switch for Hg(2+). This switch system exhibited excellent selectivity toward Hg(2+) by fluorescence (FL), (1)H NMR spectroscopy and the atomi...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید