نتایج جستجو برای: spectrophotometric detection

تعداد نتایج: 577224  

Journal: :Applied optics 2003
Vincent Loriette Claude Boccara

A collinear photothermal detection bench is described that makes use of a position-modulated heating source instead of the classic power-modulated source. This new modulation scheme increases by almost a factor 2 the sensitivity of a standard mirage bench. This bench is then used to measure the absorption coefficient of OH-free synthetic fused silica at 1064 nm in the parts per 10(6) range, whi...

Journal: :Investigative ophthalmology & visual science 1980
J Emmerton J Schwemer I Muth P Schlecht

Spectrophotometric and microspectrophotometric measures of relative spectral transmission were obtained from the cornea, lens, and vitreous body and from the whole eye of young and adult pigeons. Transmission was above 90% throughout the visible spectrum and was maintained at or above 50% into the near-UV at 310 nm. No age-related changes in transmission were found. The results concur with the ...

Journal: :Micromachines 2016
Hsiang-Li Wang Chien-Hung Chu Sing-Jyun Tsai Ruey-Jen Yang

General biochemistry detection on paper-based microanalytical devices (PADs) uses pipette titration. However, such an approach is extremely time-consuming for large-scale detection processes. Furthermore, while automated methods are available for increasing the efficiency of large-scale PAD production, the related equipment is very expensive. Accordingly, this study proposes a low-cost method f...

Journal: :Antimicrobial agents and chemotherapy 2014
Monica Osterblad Antti J Hakanen Jari Jalava

The Carba NP test was evaluated against a panel of 61 carbapenemase-producing bacterial species (15 producing class A carbapenemases, 15 producing class D carbapenemases, and 31 producing metallo-β-lactamases) and against 111 isolates with non-wild-type carbapenem susceptibility but not producing carbapenemase. Carbapenemase production was verified by PCR and UV-spectrophotometric measurement o...

2012
Milton K. Sasaki Simone Vicente Viviane Grassi Elias A.G. Zagatto

Simultaneous determinations exploiting the rates of reactions of different analytes with a common reagent, often referred to as differential kinetic analysis, is efficiently implemented in the flow analyser. To this end, specific strategies for pumping, commuting and/or detecting have been proposed. This review critically discusses the potentialities, limitations and application ranges of the d...

2002
Qun Sun Huitong Wang Shifen Mou

A method was established for the simultaneous determination of germanium and tin in one run by ion chromatography. Using a selected eluent, Ge and Sn were separated on a bifunctional ion-exchange column, followed by a postcolumn chromogenic reaction and spectrophotometric detection at 520 nm. The whole procedure was completed within 5 min with high sensitivity and selectivity at the low-/zg/1 l...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2006
Hiromi Takiguchi Azusa Tsubata Makoto Miyata Tamao Odake Hiroki Hotta Tomonari Umemura Kin-ichi Tsunoda

A flow injection analysis system was built with a liquid core waveguide spectrophotometric detector using an 80 cm Teflon AF-1600 capillary tube (2,2-bistrifluoromethyl-4,5-difluoro-1,3-dioxole/tetrafluoroethylene). The system was applied to determine nitrite ion in river water samples. The lower limit of detection for nitrite was 2.1 nmol dm(-3) (0.1 ng dm(-3) as NO(2)(-)) and the relative sta...

Journal: :Organic & biomolecular chemistry 2015
S M Forget A Jee D A Smithen R Jagdhane S Anjum S A Beaton D R J Palmer R T Syvitski D L Jakeman

Cps2L, a thymidylytransferase, is the first enzyme in Streptococcus pneumoniae L-rhamnose biosynthesis and an antibacterial target. We herein report the evaluation of six sugar phosphate analogues selected to further probe Cps2L substrate tolerance. A modified continuous spectrophotometric assay was employed for facile detection of pyrophosphate (PPi) released from nucleotidylyltransfase-cataly...

2008
P. P. Sancheti V. M. Vyas Manali Shah Poonam Karekar Y. V. Pore

A simple, sensitive, rapid, accurate and precise spectrophotometric method has been developed for the estimation of bicalutamide in bulk and pharmaceutical dosage forms. Bicalutamide shows maximum absorbance at 272 nm with molar absorptivity of 2.3399×10(4) l/mol/cm. Beer's law was obeyed in the concentration range of 1.5-18 μg/ml. The limit of detection and limit of quantification were found t...

Journal: :Journal of AOAC International 2002
José R C Rocha Cristiane X Galhardo Maria Auxiliadora E Natividade Jorge C Masini

This paper presents a method for the determination of phenylephrine hydrochloride in pharmaceuticals by spectrophotometric flow injection analysis exploiting the reaction with potassium ferricyanide and 4-aminoantipyrine, which leads to the formation of a condensation product with strong absorptivity at 500 nm. The linear dynamic range was between 0.95 and 9 mg/L, with a limit of detection of 0...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید