نتایج جستجو برای: screw removal
تعداد نتایج: 157088 فیلتر نتایج به سال:
PURPOSE To review 9 cases of mechanical failure of the volar locking plate for distal radial fractures. METHODS Records of 374 consecutive patients who underwent volar locking plating for distal radial fractures were reviewed. Mechanical failures of the volar locking plate were defined as plate breakage or bending, screw breakage or loosening, or collapse of articular fragments resulting in i...
STUDY DESIGN It is a multicenter, controlled case study review of a big scale of pedicle-screw procedures from January 2000 to June 2010. The outcomes were compared to those with no implant failure. PURPOSE The purpose of this study was to review retrospectively the outcome of 100 patients with implant failure in comparison to 100 control-patients, and to study the causes of failure and its p...
Background and aims. Because of compromised angulations of implants, the abutments are sometimes prepared. The purpose of this study was to investigate the effect of removing one wall of the implant abutment on the retention of cement-retained crowns. Materials and methods. Four prefabricated abutments were attached to analogues and embedded in acrylic resin blocks. The first abutment was left ...
Case Presentation. Implant prostheses are a successful treatment for replacing missing teeth. However, this treatment modality can have biological and mechanical complications causing serious problems for the dentist, as demonstrated in this clinical case. The patient presented with a fractured screw and a severely damaged implant hex connection that corresponded to the second premolar, upper l...
INTRODUCTION Biomechanically proximal femoral nail (PFN) is a better choice of implant, still it is associated with screw breakage, cut out of screw through femoral head, Z effect, reverse Z effect, and lateral migration of screws. The purpose of this study is to evaluate the results of augmented PFN in terms of prevention of postoperative complications and failure rates in unstable trochanteri...
PURPOSE To evaluate the implant-abutment interface area and the abutment screw loosening value when diamondlike carbon (DLC)-coated or titanium screws were used before and after cyclic loading. MATERIALS AND METHODS Thirty-six implants were divided into four groups according to the type of connection (external hexagon [EH] or internal hexagon [IH]) and the type of abutment screw (with [EHD/IH...
Although the clinical and biomechanical advantages of pedicle screws are well documented, the accuracy of their insertion is always a concern.Injury of neurovascular structures could be devastating. Perforation of the aorta from posteriorly placed screws is fortunately rare but could end up being lethal. We present a review of the current literature along with two illustrative cases with aorta ...
OBJECTIVE The purpose of this comparison case study is to show a potential complication associated with atlantoaxial fusion, and the preoperative evaluation that could help to avoid it. BACKGROUND DATA The use of lateral mass screw fixation in atlantoaxial fusion has provided surgeons the ability to create rigid fixation, with a high success rate of fusion. While the use of screws for fixat...
The aim of this study was to verify whether screw abutment lubrication can generate higher preload values compared to non-lubricated screws, a titanium abutment was screwed onto an implant analog and scanned with the Procera System to generate 20 zirconia abutments. MKIII Brånemark implants were clamped to a precision torque device, and the abutments were distributed in dry and wet groups with ...
The aim of this biomechanical study was to investigate the role of the dorsal vertebral cortex in transpedicular screw fixation. Moss transpedicular screws were introduced into both pedicles of each vertebra in 25 human cadaver vertebrae. The dorsal vertebral cortex and subcortical bone corresponding to the entrance site of the screw were removed on one side and preserved on the other. Biomecha...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید