This case report aims to evaluate safety, efficacy and feasibility of anterior surface imaging by a novel point-source reflection topographer, in comparison to four other corneal imaging modalities. A 17-year-old female patient, clinically diagnosed with chronic herpetic keratitis in her left eye was imaged by a novel multicolored-spot reflection topography system. We comparatively investigated...
A lens coloboma is not a true coloboma; it is just a zonular absence that causes a defect in the lens equator and hence a more spherical lens. It can be isolated or in association with iris, choroid or retinal colobomas. Typically the defect is present at the site of the embryonic fissure, but it can be present elsewhere. This congenital defect can cause amblyopia, especially when it is associa...
PURPOSE To investigate the test-retest variability of and factors associated with the corneal deformation response, and evaluate its impact on IOP measurement. METHODS Forty normal and 140 glaucoma suspect/glaucomatous eyes of 104 individuals were prospectively included for repeated measurements of corneal deformation response by an ultra-high-speed Scheimpflug camera, followed by corneal hys...
Patterned illumination can be used to improve lateral resolution, provide optical sectioning, and to reduce illumination dose. For example, in Structured Illumination Microscopy (SIM), spatially periodic illumination patterns are used to double the resolution [1]. The use of a Spatial Light Modulator (SLM), such as a Digital Micro-mirror Device (DMD), gives full control over the illumination pa...
PURPOSE To evaluate the agreement among Pentacam, Orbscan and ultrasound (US) pachymetry for measurement of central corneal thickness (CCT) in thin corneas with normal topographic pattern. METHODS We included 88 eyes of 44 refractive surgery candidates with thinnest pachymetric readings of 500 micrometers (μm) or less on Orbscan, a normal topographic pattern, no sign of keratoconus, and best ...
RESUMO Objetivo Avaliar a precisão da tomografia corneana com imagens de Scheimpflug (Pentacam® AXL, OCULUS, Wetzlar, Alemanha) nos padrões escaneamento 25 e 50 imagens, verificando sua repetibilidade reprodutibilidade em olhos normais, ceratocone após crosslinking. Métodos Estudo prospectivo, transversal, misto, no qual foram incluídos os pacientes que tinham córneas ou ceratocone; não realiza...
We present a method, termed distributed scanning OCT (DSOCT), which reduces the effects of patient motion on corneal biometry utilizing current-generation clinically available spectral domain optical coherence tomography (SDOCT) systems. We first performed a pilot study of the power spectrum of normal patient axial eye motion based on repeated (M-mode) SDOCT. Using DSOCT to reduce the effects o...
PURPOSE To evaluate repeatability and reproducibility of anterior corneal power measurements obtained with a new corneal topographer OphthaTOP (Hummel AG, Germany) and agreement with measurements by a rotating Scheimpflug camera (Pentacam HR, Oculus, Germany) and an automated keratometer (IOLMaster, Carl Zeiss Meditec, Germany). METHODS The right eyes of 79 healthy subjects were prospectively...