نتایج جستجو برای: scatter dose

تعداد نتایج: 321996  

Journal: :Physics in Medicine and Biology 2021

Abstract Proton therapy treatment for lungs remains challenging as images enabling the detection of inter- and intra-fractional motion, which could be used proton dose adaptation, are not readily available. 4D computed tomography (4DCT) provides high image quality but is rarely available in-room, while in-room cone beam (4DCBCT) suffers from limitations stemming mostly scatter detection. This s...

Journal: :journal of medical signals and sensors 0
daryoush shahbazi-gahrouei mehri damoori mohammad bagher tavakoli masoud moslehi

to improve the accuracy of the activity quantification and the image quality in scintigraphy, scatter correction is a vital procedure. the aim of this study is to compare the accuracy in calculation of absorbed dose to patients following bone scan with 99m tc-marked diphosphonates ( 99m tc-mdp) by two different methods of background correction in conjugate view method. this study involved 22 pa...

Journal: :Spine 2016
Kazuta Yamashita Kosaku Higashino Keizo Wada Masatoshi Morimoto Mitsunobu Abe Yoichiro Takata Toshinori Sakai Yoshihiro Fukui Koichi Sairyo

STUDY DESIGN Using fresh cadavers, real-time dosimeters were used to estimate the radiation exposure dose from C-arm fluoroscopy to surgeons, medical staff, and patients during various procedures. OBJECTIVE The aim of this study was to evaluate the radiation exposure dose from C-arm fluoroscopy, which is used to generate real-time images of the human body, under a variety of conditions and in...

Objective(s): To investigate and compare quantitative accuracy of kidney absorbed dose measures made from both 2D and 3D imaging in patients receiving 177LuDOTATATE (Lutate) for treatment of neuroendocrine tumours (NETs). Methods: Patients receiving Lutate therapy underwent both whole body planar imaging and SPECT/CT imaging over the kidneys at time points 0.5, 4, 24, and 96-120 hours after inj...

2016
Cheng-Han Yu

(a) Using R, fit 3 binomial GLMs for these data corresponding to 3 link functions, logit, probit, and complementary log-log. Perform residual analysis for each model, using the deviance residuals. Obtain fitted values, π̂i, under each model and compare with observed proportions, yi/mi. Obtain the estimated dose-response curve under each model by evaluating π̂(x) = g(β̂1 + β̂2x) over a grid of value...

Journal: :iranian journal of medical physics 0
mohammad taghi bahreyni toossi medical physics research center, medical physics department, mashhad university of medical sciences, mashhad, iran

introduction spect projections are contaminated by scatter radiation, resulting in reduced image contrast and quantitative errors. backscatter constitutes a major part of the scatter contamination in lower energy windows. the current study is an evaluation of the effect of backscatter material on fwhm and image quality investigated by monte carlo simulation. materials and methods simind program...

Journal: :Physics in medicine and biology 2009
Stephen F Kry Rebecca M Howell Jerimy Polf Radhe Mohan Oleg N Vassiliev

The requirements for shielding a treatment vault with a Varian Clinac 2100 medical linear accelerator operated both with and without the flattening filter were assessed. Basic shielding parameters, such as primary beam tenth-value layers (TVLs), patient scatter fractions, and wall scatter fractions, were calculated using Monte Carlo simulations of 6, 10 and 18 MV beams. Relative integral target...

Journal: :AJNR. American journal of neuroradiology 2009
A C Miracle S K Mukherji

Conebeam x-ray CT (CBCT) is a developing imaging technique designed to provide relatively low-dose high-spatial-resolution visualization of high-contrast structures in the head and neck and other anatomic areas. This first installment in a 2-part review will address the physical principles underlying CBCT imaging as it is used in dedicated head and neck scanners. Concepts related to CBCT acquis...

2017
Carlos F. Uribe Pedro L. Esquinas Jesse Tanguay Marjorie Gonzalez Emilie Gaudin Jean-Mathieu Beauregard Anna Celler

BACKGROUND The aim of the study is to assess accuracy of activity quantification of 177Lu studies performed according to recommendations provided by the committee on Medical Internal Radiation Dose (MIRD) pamphlets 23 and 26. The performances of two scatter correction and three segmentation methods were compared. Additionally, the accuracy of tomographic and planar methods for determination of ...

Journal: :The Journal of veterinary medical science 2004
Masashi Miyake Takahiro Yaguchi Koh-ichi Saze Janhui Wang Toshiyuki Ogawa Yoshio Endo Yasuyuki Suzuta Masayuki Okazaki Yoshihisa Haga Takashi Waki Susumu Y Takahashi Yoshimi Yamamoto Shigehiro Iwabuchi

Hepatocyte growth factor (HGF) is a pleiotropic cytokine that stimulates a wide array of cellular targets, including hepatocytes and other epithelial cells, melanocytes, endothelial and hematopoietic cells. We have cloned a different form of cDNA, with a deletion of 15 base pairs predicted to result in the loss of 5 amino acids from the first kringle domain. To investigate the biological activi...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید