there exist a number of factors that affect the quality laser scanner. in other words, the accuracy of a terrestrial scanner is limited extensively by systematic errors and thus must be calibrated. indeed, calibration is a prerequisite for obtaining 3d precise and reliable data from point clouds. until now, several models have been proposed to improve the accuracy of laser scanner data, most of...

Journal: :Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering 2007

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2015
John J Sunderland Paul E Christian

UNLABELLED The Clinical Trials Network (CTN) of the Society of Nuclear Medicine and Molecular Imaging (SNMMI) operates a PET/CT phantom imaging program using the CTN's oncology clinical simulator phantom, designed to validate scanners at sites that wish to participate in oncology clinical trials. Since its inception in 2008, the CTN has collected 406 well-characterized phantom datasets from 237...

2006
JM Smyth DG Sutton JG Houston

PURPOSE The development of flat panel detector technology has resulted in renewed interest in the possibility of generating CT-like images from rotational angiographic acquisitions. At least two commercial products now use cone beam reconstruction software in conjunction with flat panel detectors to produce such images. The purpose of the work presented here is to report on image quality obtain...

Ansari , Amir , Honarvar , F., Mahboobipour , Vahid ,

 The results of ultrasonic tests are usually displayed as A-scan signals. In an A-scan signal, reflections of ultrasonic wave form different reflectors are shown as sharp echoes on a time by amplitude display. Interpretation of these echoes can sometimes be quite difficult and usually requires knowledgeable and experienced specialists. There exist other methods of displaying the ultrasonic test...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2005
Marco Brambilla Chiara Secco Marco Dominietto Roberta Matheoud Gianmauro Sacchetti Eugenio Inglese

UNLABELLED This article reports the results of performance measurements obtained for the lutetium oxyorthosilicate (LSO)-based whole-body PET/CT scanner Biograph 16 HI-REZ with the National Electrical Manufacturers Association (NEMA) NU 2-2001 standard. The Biograph 16 HI-REZ combines a multislice (16-slice) spiral CT scanner with a PET scanner composed of 24.336 LSO crystals arranged in 39 rin...