نتایج جستجو برای: profile stent system

تعداد نتایج: 2447894  

2017
Jun-ichi Koyama Yoshiki Hanaoka Takafumi Kiuchi Tetsuo Sasaki Takahiro Murata Atsushi Sato

Objective: We formulated a simulator system for catheter intervention training by developing a sliding table and an electrically controlled camera-holding C-arm and combining them with the silicone vessel model EndoVascular Evaluator (EVE). We performed simulation of mechanical thrombectomy using this system and evaluated its usability for simulation training. Methods: After three experts in ne...

Journal: :Stroke 2007
David Fiorella Elad I Levy Aquilla S Turk Felipe C Albuquerque David B Niemann Beverly Aagaard-Kienitz Ricardo A Hanel Henry Woo Peter A Rasmussen L Nelson Hopkins Thomas J Masaryk Cameron G McDougall

BACKGROUND AND PURPOSE The current report details our initial periprocedural experience with Wingspan (Boston Scientific/Target), the first self-expanding stent system designed for the treatment of intracranial atheromatous disease. METHODS All patients undergoing angioplasty and stenting with the Gateway balloon-Wingspan stent system were prospectively tracked. RESULTS During a 9-month per...

2011
Luciano Maurício de Abreu Filho Antonio Artur da Cruz Forte Marcos Kiyoshi Sumita Desidério Favarato George César Ximenes Meireles

BACKGROUND In Brazil, despite the recommendations of the Brazilian Society of Hemodynamics and Interventional Cardiology, the National Health System has not yet approved the use of drug-eluting stents. In percutaneous coronary interventions performed in the public and part of the private health care system, bare metal stents are used as the only option. Therefore, new information on bare metal ...

2017
Woo Hyun Paik Do Hyun Park

Endoscopic ultrasound (EUS)-guided drainage is evolving and no standardized technique for it has been established yet. Availability of dedicated devices and accessories also are lacking. Anderloni et al. described a new technique of stent deployment named Intra Channel Stent Release Technique (ICSRT) in EUS-guided drainage [1], which is summarized as follows: deployment of the proximal part of ...

Journal: :archives of trauma research 0
stephan brand trauma department, hannover medical school (mhh), hannover, germany; trauma department, hannover medical school (mhh), hannover, germany. tel: +49-5115322026, fax: +49-5115325877 ingo breitenbach department of cardiothoracic and vascular surgery, public hospital braunschweig, braunschweig, germany philipp bolzen department of diagnostic radiology, hannover medical school, hannover, germany maximilian petri trauma department, hannover medical school (mhh), hannover, germany christian krettek trauma department, hannover medical school (mhh), hannover, germany omke teebken division of vascular surgery, department of cardiothoracic, transplantation and vascular surgery, hannover medical school, hannover, germany

conclusions due to more sophisticated diagnostic tools and surgical approaches, mortality and morbidity of blunt aortic injuries were significantly reduced over the years compared to thoracic endovascular aortic repair and or over two different time periods. objectives the aim of the present study was to retrospectively evaluate the mortality and morbidity with either treatment option. therefor...

Journal: :Journal of Electrochemical Science and Engineering 2023

Medical implants and other biomaterials are used by millions of individuals all over the globe to restore lost bodily functions due injury or illness. Many these fail after a short time have difficulties, despite fact that they play important roles in keeping person's life safe increasing quality their lives. It is lack biocompatibility has proven be biggest downfall biomaterials. Investments t...

Journal: :AJNR. American journal of neuroradiology 2005
Stephen P Lownie David M Pelz Donald H Lee Suleyman Men Irene Gulka Paul Kalapos

BACKGROUND AND PURPOSE One of the limitations of carotid artery angioplasty is the potential for embolic stroke. Our purpose was to assess whether the force of a self-expanding stent alone is usually sufficient to dilate severely stenotic atherosclerotic plaques without the deliberate use of an angioplasty balloon. If so, the procedural stroke risk might be reduced. METHODS Over a 30-month pe...

2009
Olavi Lukkarinen

The first aim of this study was to evaluate the biocompatibility and degradation as well as potential clinical use of a new biodegradable PLGA (copolymer of L-lactide and glycolide acid) urethral stent with a braided mesh configuration. The second and at the same time, the main objective of this study was to develop a new drug-eluting biodegradable urethral stent. The biocompatibility profile o...

Journal: :Endoscopy 2016
Shupeng Wang Jintao Guo Siyu Sun Xiang Liu Sheng Wang Nan Ge Guoxin Wang

Endoscopic ultrasound (EUS)-guided hepaticogastrostomy with a fully covered metal stent is an option for malignant biliary obstruction after a failed endoscopic retrograde cholangiopancreatography (ERCP) [1–3]; however, migration of the stent can be a fatal complication [3, 4]. We report a case in which a migrated stent was successful reset using a foreign body forceps. A 73-year-old woman deve...

Journal: :nephro-urology monthly 0
ali reza ghadian nephrology and urology research center, baqiyatallah university of medical sciences, tehran, ir iran; nephrology and urology research center, baqiyatallah university of medical sciences, tehran, ir iran. tel: +98-9123197306, fax:-+98-2181262073 fatemeh heidari nephrology and urology research center, baqiyatallah university of medical sciences, tehran, ir iran ali reza afkhami nephrology and urology research center, baqiyatallah university of medical sciences, tehran, ir iran

background the most important surgical complications of renal transplantation are stenosis and obstruction of anastomosis of the ureter to the bladder. hence, routine use of ureteral stents to prevent such complications seems logical; however, the optimal time to remove the ureteral stent is still controversial. objectives the purpose of this study was to compare the benefits and complications ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید