نتایج جستجو برای: pressure transducer

تعداد نتایج: 425345  

Journal: :Anais da Academia Brasileira de Ciencias 2011
Viviane Soares Fábio B Rodrigues Marcus F Vieira Maria Sebastiana Silva

The respiratory muscles can present fatigue and even chronic inability to generate force. So, reliable devices are necessary to their evaluation. The aim of this study is to evaluate the MEP (Maximal Expiratory Pressure) values of individuals between 20 and 25 years old and to validate a protocol using a pressure transducer and a signal conditioner comparing it with the digital manometer. We ev...

Journal: :British medical journal 1975
S J Jachuck P S Ramani F Clark R M Kalbag

Serial electrocardiographic (E.C.G.) recordings were taken in seven patients suffering from intracranial conditions, for which their intracranial pressure was directly and continuously monitored with a Konigsberg extradural transducer. The E.C.G. changes observed in patients with raised intracranial pressure were prominent U waves, ST-T segment changes, notched T waves, and shortening and prolo...

Journal: :Canadian journal of anaesthesia = Journal canadien d'anesthesie 1989
M A Lyew S R Pinto J C Bevan

A simple instrument for measuring adductor pollicis tension in children has been devised. The thumb sensor utilizes a thin conical rubber seal obtained from a 5, 10 or 20 ml Becton Dickinson syringe. A syringe barrel of similar size, fixed at right angles to the sensor, forms a handle for the fist. The sensor is linked to a pressure transducer with non-compliant tubing. Pressure output of the s...

Journal: :The Journal of experimental biology 1988
J R Lighton

Journal: :Journal of rehabilitation research and development 1984
N P Reddy V Palmieri G V Cochran

To assess the performance of transducers used clinically to measure pressure at the skin-cushion interface of seated patients, transducers were placed between slabs of gel and/or foam materials compressed between platens. The recorded pressures consistently exceeded the nominal pressures calculated using the surface area of the slabs. This overestimation, observed in both miniature diaphragm tr...

Journal: :British journal of anaesthesia 1991
C H Hackman P S Tan M K Chakrabarti J G Whitwam

A new optical pressure transducer system (Viggo) has been assessed and compared with a standard P10 transducer (Spectramed) using a similar 20-gauge cannula, both in vitro in terms of linearity and frequency response and in vivo using an animal model. The linearity of the transducers was comparable; the resonant frequencies were 106 Hz and 75 Hz, respectively. However, the resonant frequency of...

Journal: :Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies 2010
Thomas Spentzas Jared Henricksen Andrea B Patters Edward Chaum

OBJECTIVE To determine whether there was a correlation between tonometric measurements of the intraocular pressure and transducer measurements of the intracranial pressure in the acute setting, and whether intraocular pressure can be used as a surrogate measure of intracranial pressure. Children with traumatic brain injuries commonly develop increased intracranial pressure requiring surgical pl...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید