نتایج جستجو برای: portable gamma camera

تعداد نتایج: 211659  

Journal: :World Journal of Surgical Oncology 2007
Carole Mathelin Samuel Salvador Sabrina Croce Norosoa Andriamisandratsoa Daniel Huss Jean-Louis Guyonnet

BACKGROUND Sentinel lymph node (SLN) procedure is now a widely accepted method of LN staging in selected invasive breast cancers (unifocal, size </= 2 cm, clinically N0, without previous treatment). Complete axillary clearance is no longer needed if the SLN is negative. However, the oncological safety of this procedure remains to be addressed in randomized clinical trials. One main pitfall is t...

Journal: :Applied sciences 2021

This paper reports the results of analysis measurements involving partial discharges (PD) occurring in air using a corona camera (UV camera). The were carried out laboratory conditions and applied two electrode systems: needle–needle needle–plate, order to obtain various electric field distributions. PDs, including variety alternatives, portable UV camera, taking into account impact gain parame...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2011
Oscar R Brouwer Renato A Valdés Olmos Lenka Vermeeren Cornelis A Hoefnagel Omgo E Nieweg Simon Horenblas

UNLABELLED The purpose of this study was to evaluate the utility of SPECT/CT and real-time intraoperative imaging with a portable γ-camera for laparoscopic sentinel node (SN) localization in stage I testicular cancer. METHODS Ten patients with clinical stage I testicular cancer were studied between November 2006 and November 2010. Their mean age was 37 y (range, 25-50 y). The primary tumors w...

Introduction: Gamma cameras are proposed for online range verification and treatment monitoring in proton therapy.  An Analytical formula was derived and validated for sensitivity of a slit collimator based on the photon fluence concept. Methods: Fluence formulation was generalized for photons distribution function and solved for high-energy point sources. The...

Journal: :iranian journal of radiation research 0
a.t. al-kinani supreme council for environment and natural reserves, doha, qatar, a.s. al-saidi s. al-anni

abstract   background : the application of du emanation for first time contaminated certain areas in the south west region of iraq after the second gulf war (1991). these contaminated areas were discovered in 1994. radioactive contamination was detected using the nuclear enterprise pcm5/1 in soil samples collected from two regions near by grazing lands. this study was done for assessment of du ...

Journal: :The European respiratory journal 1997
S G Devadason M L Everard C MacEarlan C Roller Q A Summers P Swift L Borgstrom P N Le Souëf

Drug delivery to patients using dry powder inhalers, such as the Turbuhaler, is believed to be influenced by the inspiratory flow used. Clinical studies have indicated that this delivery system can be used effectively by children. However, it is not known how the total and weight-corrected dose delivered to the airways varies with age. A deposition study using technetium-99m (99mTc)-labelled bu...

Journal: :Journal of Instrumentation 2022

Abstract Six methods for the automatic detection of scintillation light splashes in a portable gamma camera are compared. Each imaging frame might contain any number (including none), and location size each splash must be identified. For real-time imaging, identified characterised quickly with minimal processing overhead. The techniques compared on their ability to accurately determine number, ...

Journal: :IJPRAI 2002
Antonio López Rafael Molina Javier Mateos Aggelos K. Katsaggelos

SPECT images are observation data acquired by a gamma-camera following an orbit around the patient’s body, at regularly spaced angles. A reconstructed image is the discrete representation of a slice or cross-section of the isotope distribution within the patient, transversal to the gamma-camera rotation axis. Bayesian reconstruction methods have been extensively used to reconstruct medical imag...

2017
John E. Lees Sarah L. Bugby Mohammed S. Alqahtani Layal K. Jambi Numan S. Dawood William R. McKnight Aik H. Ng Alan C. Perkins

The development of low profile gamma-ray detectors has encouraged the production of small field of view (SFOV) hand-held imaging devices for use at the patient bedside and in operating theatres. Early development of these SFOV cameras was focussed on a single modality-gamma ray imaging. Recently, a hybrid system-gamma plus optical imaging-has been developed. This combination of optical and gamm...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید