Objectives: For the simultaneous estimation of deferiprone in pharmaceutical formulations, a high-performance liquid chromatographic technique that is straightforward, reproducible, and effective was developed. Methods: The Advanced Technologies Ltd HPLC system with UV-2075 UV-Vis detector, P-2080 pump, Hypersil C18 column (250 × 4.6 mm) used to perform separation. ACN water make up mobile phas...