نتایج جستجو برای: pedicle

تعداد نتایج: 5739  

2014
Ilkka Helenius Mikko Mattila Tuomas Jalanko

OBJECTIVES Untreated severe scoliosis is associated with increased mortality and remains a significant surgical challenge. Few studies have reported mortality after the surgical treatment of severe scoliosis beyond a 2-year follow-up. The objectives of this study were to evaluate mortality beyond standard 2-year follow-up and compare radiographic outcomes using hybrid or pedicle screw instrumen...

2016
Michael Siu Hei Tse Chi Hin Chan Kam Kwong Wong Wing Cheung Wong

STUDY DESIGN Retrospective study. PURPOSE To analyze the quantitative anatomy of C7 vertebra for insertion of lateral mass screws and pedicle screws in Southern Chinese patients. OVERVIEW OF LITERATURE C7 lateral mass is smaller when compared to other subaxial cervical levels, which limits the length of lateral mass screws that can be used. Some studies have suggested pedicle screws for bet...

Journal: :Orthopedics 2013
Lu Mao Guang-Dong Chen Xiao-Min Xu Zhe Guo Hui-Lin Yang

Currently, bilateral pedicle screw fixation is the standard of instrumentation, providing rigid fixation and an increased fusion rate. However, due to the excessive rigidity of the system, this instrumentation has been suspected to cause degeneration of adjacent segments. Alternatively, less rigid unilateral pedicle fixation is considered to be as effective as bilateral constructs. Few studies ...

2013
NAJMUS SAHAR SAQIB ARIF QURRAT-UL-AIN AFZAL MUBARIK AHMED JEHAN ARA QASIM CHAUDHRY

Red chili is amongst the important market commodities mainly for its pungency, color and their respective therapeutic significances. However, the persistence of aflatoxin contamination in chilies at higher levels is raising the health and economic risks. Post harvest practices may play as crucial role to make the red chilies physically damaged that may lead to increase the levels of aflatoxins....

Journal: :Clinical orthopaedics and related research 1999
S C Ludwig D L Kramer A R Vaccaro T J Albert

The use of posterior cervical spine fixation has become increasingly popular in recent years. Dissatisfaction with lateral mass fixation, especially at the cervicothoracic junction, has led spine surgeons to use cervical pedicle screw fixation for reconstruction in numerous cervical spine disorders. The biomechanical advantage of a three-column fixation device implanted to secure an unstable ce...

2012
Sung-Uk Kuh Young-Sung Kim Hong-June Choi Kyung-Hyun Kim Jeong-Yoon Park Hyun-Yong Jeong Dong-Kyu Chin Keun-Su Kim Young-Sul Yoon Yoon-Chul Lee Yong-Eun Cho

OBJECTIVE Polyaxial pedicle screws are a safe, useful adjunct to transpedicular fixation. However, the large screw head size can cause soft tissue irritation, high rod positioning, and facet joint injury. However, the mechanical resistance provided by small and low profile pedicle screws is very limited. We therefore developed a novel, low profile pedicle screw using grooving and blasting treat...

2014
Cengiz Isik Kamil Cagri Kose Mustafa Erkan Inanmaz Suleyman Murat Tagil Hakan Sarman

A cadaver study aims to determine the mechanisms of medial pedicle wall violation after a correct cannulation of the pedicle. The study presents finding out the effect of insertion angle and insertion force on medial wall violation. We used 100 lumbar pedicles of cadavers. Special wooden blocks were produced to simulate a fixed angle fault after a correct pedicle cannulation. Pedicles were divi...

2015
Lijun Wu Tianlan Zhao Daojiang Yu Qi Chen Wenya Han Wenyuan Yu Wei Sun Maria Cristina Vinci

OBJECTIVE To evaluate the dynamic change of CD34 level during the survival process of narrow pedicle flaps. METHODS Twenty-five white pigs were randomly and equally divided into 5 experimental groups. Five different type of narrow pedicle with different length-to-width ratio were employed, and each type of narrow pedicle was covered with 5 different size random flaps and which was classified ...

Journal: :The Journal of bone and joint surgery. British volume 2001
D P Reidy D Houlden P C Nolan M Kim J A Finkelstein

We prospectively studied the use of intercostal EMG monitoring as an indicator of the accuracy of the placement of pedicle screws in the thoracic spine. We investigated 95 thoracic pedicles in 17 patients. Before insertion of the screw, the surgeon recorded his assessment of the integrity of the pedicle track. We then stimulated the track using a K-wire pedicle probe connected to a constant cur...

2014
kadir kotil

Generally, bilateral pedicle screw fixation after Minimal Invasive (MIS) TLIF is accepted as a standard procedure for treating symptomatic spinal pathologies, such as degenerative spinal stenosis, spondylolisthesis, recurrent disc herniation, postlaminectomy instability, and deformity (10). Some authors have recently demonstrated that unilateral pedicle screw fixation is as effective for spinal...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید