نتایج جستجو برای: oil tank floor
تعداد نتایج: 184780 فیلتر نتایج به سال:
The present paper deals with the optimization of a multi-energy district boiler (La Rochelle, France) which supplies domestic hot water and heats residential and public buildings, using renewable and fossil resources. First, a combination of white, grey and black boxes was used to model the plant, thanks to a modular approach. Next, a stratified thermal storage tank was modelled and completed t...
The liquid cargo replenishment decision based on ship’s stability, strength and the floating state is a multiobjective optimization problem. The mathematical model of multi-objective is built in this paper. Aiming to obtain the feasible solution, the adaptive step ergodic of permutation and combination is applied in terms of the cargo oil tank and the water ballast tank. particle swarm optimiza...
The surrounding rock stability of an underground cavern group is important issue in the process excavation, which has characteristics large displacement, discontinuity and uneven deformation, so calculation analysis are very complicated. optimized discontinuous deformation for failure method was adopted to analyze a real engineering under different excavation schemes. cracking schemes, depth cr...
The culture conditions of a multiphase fermentation involving morphologically complex mycelia were simulated in order to investigate the influence of mycelial morphology (Trichoderma harzianum) on castor oil and air dispersion. Measurements of oil drops and air bubbles were obtained using an image analysis system coupled to a mixing tank. Complex interactions of the phases involved could be cle...
Oil and gas deposits in the Alaskan Arctic are estimated to contain up to 40 percent of the remaining undiscovered crude oil and oil-equivalent nature gas within U.S. jurisdiction. Most (65 to 70 percent) of these estimated reserves are believed to occur offshore beneath the shallow, ice-covered seas, of the Alaskan continental shelf. Offshore recovery operations for such areas are far from rou...
An LPG tank fabncated by a major manufacturer in the late 1940s with rolled skid plate, commonly used in steel floor construction, burst catastrophcally under direct sunlight. The rupture caused extensive property damage and fatal injury. Metallurgxal analysis revealed that at time of fabrication the full penetration longitudinal seam weld of the tank had been torch cut and then reconnected wit...
Štúdium viazania stopových prvkov v sedimente vodnej nádrže Ružín Pre účely posúdenia možnosti využitia fyzikálnych a fyzikálno-chemických metód separácie, vybraná vzorka sedimentu z Ružína bola podrobené 5-stupňovej procedúre sekvenčnej extrakcie (SE) podľa Tessiera (Tessier et al., 1979) a Horowitza (Horowitz, 1991). Vo výluhoch bolo stanovované zastúpenie konštitučných (Fe, Mn, Ca a Mg) ako ...
For examination and diagnostics of the insulation quality of high voltage devices the measurement of partial discharge (PD) is accomplished. The conventional PD measurement according to IEC60270 is in some situations not sensitive enough because of the high interference level in field. The development of an unconventional measuring method using electromagnetic probes is presented. These probes ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید