نتایج جستجو برای: ocular implant

تعداد نتایج: 102016  

Journal: :Vision Research 2001
M. Dubbelman G. L. Van der Heijde

Scheimpflug slit images of the crystalline lens are distorted due to the refracting properties of the cornea and because they are obliquely viewed. We measured the aspheric curvature of the lens of 102 subjects ranging in age between 16 and 65 years and applied correction for these distortions. The procedure was validated by measuring an artificial eye and pseudophakic patients with intraocular...

Journal: :Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery 2015
Thomas Gander Harald Essig Philipp Metzler Daniel Lindhorst Leander Dubois Martin Rücker Paul Schumann

Fractures of the orbital wall and floor can be challenging due to the demanding three-dimensional anatomy and limited intraoperative overview. Misfitting implants and inaccurate surgical technique may lead to visual disturbance and unaesthetic results. A new approach using individually manufactured titanium implants (KLS Martin, Group, Germany) for daily routine is presented in the current pape...

Journal: :Journal of the Medical Association of Thailand = Chotmaihet thangphaet 2008
Chalao Pongprayoon

OBJECTIVE To determine the incidence of complications and the outcome associated with the use of three kinds of ocular porous implants. MATERIAL AND METHOD Retrospective review of 133 consecutive case series. All patients undergoing orbital implantation either primary or secondary implantation of 49 coral hydroxyapatite, 43 human bone hydroxyapatite and 39 bovine bone hydroxyapatite from Sept...

2012
G. M. L. L. da Silva R. de C. F. de Lima P. R. M. Lyra D. K. E. de Carvalho A. Fernandes

This study analyzes the heat transfer in human eyes following implantation of retinal prostheses using an axisymmetric formulation of the Finite Volume Method. The model used consisted of a vertex centered unstructured grid finite volume method in an edgebased data structure and an explicit time integration. The results of the finite volume thermal analysis in ocular tissues were determined in ...

2013
Tizana Marchino José I. Vela Francisca Bassaganyas Saskia Sánchez José A. Buil

PURPOSE To report the first case of acute endophthalmitis caused by Alloiococcus otitidis after a dexamethasone intravitreal implant. METHODS A 74-year-old female was treated with intravitreal Ozurdex(®) in her left eye for central retinal vein occlusion (CRVO). Best-corrected visual acuity (BCVA) in the eye was 4/20. Intravitreal injection was uneventful. At 48 h after injection, she develop...

پایان نامه :دانشگاه آزاد اسلامی واحد علوم پزشکی تهران - دانشکده پزشکی 1390

هدف:بررسی نتایج عمل تخلیه چشم ((evisceration و کارگذاری implant در بیماران مراجعه کننده به کلینیک مرکزی شهر در سالهای 1388و 1389 روش مطالعه:این مطالعه که از نوع توصیفی مقطعی بوده در 22 بیمار مراجعه کننده به کلینیک مرکزی شهر که تحت عمل evisceration با روش implant گذاری نوین قرار گرفته اند انجام شده است. بیماران بعد از ثبت اطلاعات دموگرافیک و سوابق چشم پزشکی و اطمینان از عدم دید کامل آنها(nlp) ...

Traveling to high altitudes can expose the eye to reduced ambient cold and low-pressure environments. These conditions can affect the physiology of the eye and may result in ocular problems and visual disturbances. In this paper, ocular disorders related to high altitudes are briefly reviewed. Then, high-altitude ocular disorders are categorized in three parts: those related to dry and cold env...

Journal: :journal of dentistry, tehran university of medical sciences 0
farhad tabatabaian assistant professor, department of prosthodontics, dental school, shahid beheshti university of medical sciences, tehran, iran. abolfazl saboury associate professor, department of prosthodontics, dental school, shahid beheshti university of medical sciences, tehran, iran. zahra sadat sobhani former student, dental school of shahid beheshti university of medical sciences, tehran, iran. vicki c petropoulos associate professor, department of preventive and restorative sciences, university of pennsylvania school of dental medicine, united states.

the effect of inter-implant distance on retention and resistance of implant-tissue-supported overdentures is lacking in the literature. an in vitro study was performed to evaluate this effect for mandibular implant-tissue-supported overdentures retained by two ball attachments.an acrylic cast of an edentulous mandible was fabricated. three pairs of implants were symmetrically placed at both sid...

Journal: :avicenna journal of dental research 0
masoumeh khoshhal department of periodontics, school of dentistry, hamadan university of medical sciences, hamadan, ir iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی همدان (hamadan university of medical sciences) fariborz vafaei department of prosthodontics, school of dentistry, hamadan university of medical sciences, hamadan, ir iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی همدان (hamadan university of medical sciences) banafsheh poormoradi department of periodontics, school of dentistry, hamadan university of medical sciences, hamadan, ir iran; department of periodontics, school of dentistry, hamadan university of medical sciences, hamadan, ir iran. tel: +98-9188124251, fax: +98-8138381085سازمان اصلی تایید شده: دانشگاه علوم پزشکی همدان (hamadan university of medical sciences) janet moradi haghgoo department of periodontics, school of dentistry, hamadan university of medical sciences, hamadan, ir iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی همدان (hamadan university of medical sciences) faezeh behgozin dentist, hamadan, ir iran neda amiri dentist, hamadan, ir iran

results the mean distances between the crestal bone and the implant shoulder in group 1 were 1.01, 1.44, and 1.93 mm at the implant placement time, and at the 6 and 12-month postoperative intervals, respectively. in group 2, these distances were 1.35, 1.20, and 1.41 mm, respectively. there were no significant differences in the marginal bone resorption between the two groups (p > 0.05). conclus...

ژورنال: بینا 2020
, ,

According to military documents, the incidence of ocular injuries significantly increases. Intraocular foreign body (IOFB) is one of the ocular damages that seriously threats vision. Many ocular injuries occurred in a war between Iran and Iraq from 1980 to 1988. The aim of the present study was to review ocular damages made by IOFB in this war, different methods of treatment and their prognosis.

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید