نتایج جستجو برای: monte carlo fluka
تعداد نتایج: 72691 فیلتر نتایج به سال:
For the production of a clinical 15 MV photon beam, the design of accelerator head assembly has been optimized using Monte Carlo based FLUKA code. The accelerator head assembly consists of etarget, flattening filter, primary collimator and an adjustable rectangular secondary collimator. Accelerators used for medical radiation therapy generate continuous energy gamma rays called bremsstrahlung r...
Monte Carlo (MC) methods are increasingly being utilized to support several aspects of commissioning and clinical operation of ion beam therapy facilities. In this contribution two emerging areas of MC applications are outlined. The value of MC modeling to promote accurate treatment planning is addressed via examples of application of the FLUKA code to proton and carbon ion therapy at the Heide...
Dose distributions of (192)Ir HDR brachytherapy in phantoms simulating water, bone, lung tissue, water-lung and bone-lung interfaces using the Monte Carlo codes EGS4, FLUKA and MCNP4C are reported. Experiments were designed to gather point dose measurements to verify the Monte Carlo results using Gafchromic film, radiophotoluminescent glass dosimeter, solid water, bone, and lung phantom. The re...
Background: Monte Carlo and experimental relative dose determination in a water phantom, due to a high dose rate (HDR) 192Ir source is presented for real energy spectrum and monochromatic at 356 keV. Materials and Methods: The dose distribution has been calculated around the 192Ir located in the center of 30 cm ×30 cm ×30 cm water phantom using MCNP4C code by Monte Carlo method. Relati...
Background: Iodine brachytherapy sources with low photon energies have been widely used in treating cancerous tumors. Dosimetric parameters of brachytherapy sources should be determined according to AAPM TG-43U1 recommendations before clinical use. Monte Carlo codes are reliable tools in calculation of these parameters for brachytherapy sources. Materials and Methods: Dosimetric param...
Introduction Shielding calculations for the GSI future project [1] have been performed using the radiation transport code FLUKA [2, 3]. FLUKA is capable of simulating hadronic and electro-magnetic interactions of particles with matter. Here the task is to attenuate radiation generated inside experimental areas or accelerators to a dose rate not larger than 0.5μSv/h at outer walls and to estimat...
The Virtual Monte Carlo concept allows performing simulations using Geant3, Geant4 or Fluka without changing the user code [1]. This concept was used as a base for developing the CbmRoot framework for the CBM collaboration [2]. In this concept, the same framework is used for simulation and data analysis. An Oracle database with a build-in versioning management is used to efficiently store the d...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید