نتایج جستجو برای: mcnp code

تعداد نتایج: 168334  

2007
S. D. Clarke S. A. Pozzi E. Padovani T. J. Downar Shaun D. Clarke Sara A. Pozzi

The most recent release of photonuclear interaction data for Monte Carlo applications is the ENDF/B-VII library. While this current version offers several improvements over its predecessors, it does not address the observed, sometimes quite significant variance in the measured data. For instance, for U, the cross-section data in the ENDF/B-VII library is consistently larger than all measurement...

2007
D. V. Fedorchenko

Design and maintenance of nuclear cycle facilities mandatory imply implementation of efficient radiation protection. Radiation environment assessment and shielding optimization require a considerable amount of numerical calculations. Nowadays mathematical modelling methods and corresponding software are widely used for such kind of problems. All the software used for radiation fields modelling ...

1999
John S. Hendricks Christopher N. Culbertson

The weight window variance reduction method in the general-purpose Monte Carlo N-Particle radiation transport code MCNP has recently been rewritten. In particular, it is now possible to generate weight window importance functions on a superimposed mesh, eliminating the need to subdivide geometries for variance reduction purposes. Our assessment addresses the following questions: (1) Does the n...

2008
Vicente Abella Rafael Miró Belén Juste Gumersindo Verdú

The purpose of this work is to obtain the voxelization of a series of tomography slices in order to provide a voxelized human phantom throughout a MatLab algorithm, and the consequent simulation of the irradiation of such phantom with the photon beam generated in a Theratron 780® (MDS Nordion) 60 Co radiotherapy unit, using the Monte Carlo transport code MCNP (Monte Carlo N-Particle), version 5...

Journal: :IEEE Transactions on Nuclear Science 1992

2004
M. Ramos S. Ferrer J. I. Villaescusa G. Verdú

The aim of this study is the development of a methodology to reconstruct the image of detail defects from a mammographic phantom employed in quality control testing. The MCNP-4c2 code has been used to model the mammography unit and the CIRS 11A (MAMMO PHANTOM SP01) mammographic phantom. This phantom is made of poly-methyl methacrilate and contains a reference point, contrast and resolution deta...

Ahmad Esmaili-Torshabi Ahmad Mosalaei Kamal Hadad Mohammad Amin Mosleh-Shirazi, Reza Faghihi, Simin Mehdizadeh Vahid Moslemi

Introduction: In brachytherapy, radioactive sources are placed close to the tumor, therefore, small changes in their positions can cause large changes in the dose distribution. This emphasizes the need for computerized treatment planning. The usual method for treatment planning of cervix brachytherapy uses conventional radiographs in the Manchester system. Nowadays, because of their advantages ...

2014
Birju P. Shah Nicholas Pasquale Gejing De Tao Tan Jianjie Ma Ki-Bum Lee

Mitochondria-targeting peptides have garnered immense interest as potential chemotherapeutics in recent years. However, there is a clear need to develop strategies to overcome the critical limitations of peptides, such as poor solubility and the lack of target specificity, which impede their clinical applications. To this end, we report magnetic core-shell nanoparticle (MCNP)-mediated delivery ...

1996
J. C. Liu S. Rokni V. Vylet R. Arora A. Justus

Neutron detection time distribution is an important factor for the dead-time correction for moderator type neutron detectors used in pulsed radiation fields. Measurements of the neutron detection time distributions of multisphere LiI detectors (2Ó, 3Ó, 5Ó, 8Ó, 10Ó and 12Ó in diameter) and AB remmeter were made inside a ANL 20-MeV electron Linac room. Calculations of the neutron detection time d...

2012
M. A. Mosleh Shirazi R. Faghihi Z. Siavashpour H.A. Nedaie S. Mehdizadeh S. Sina

Accuracy of treatment planning systems may significantly influence the efficacy of brachytherapy. The purpose of this work is a detailed, varied and independent evaluation of an in-house brachytherapy treatment planning software called STPS. Operational accuracy of STPS was investigated. Geometric tests were performed to validate entry and reconstruction of positional information from scanned o...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید