B. Bansal X. D. Chen

* Current address: Fonterra Co-operative Group Ltd, Private Bag 11029, Palmerston North, New Zealand Email: [email protected] ABSTRACT Fouling of heat exchangers in the dairy industry has been investigated extensively and a large number of studies are reported in literature. This review focuses on the mechanisms of milk fouling, detailing the role of protein denaturation and aggregation...

2017
Xing Zheng Frederik Zietzschmann Stephan Plume Hendrik Paar Mathias Ernst Martin Jekel

The present work focuses on understanding and control of biopolymer fouling in ultrafiltration of a typical surface water and nearby secondary effluent for direct and indirect portable use. Characterization results show that both kinds of biopolymers are of similar molecular weight. Longer than one year water quality monitoring results show that the C/N ratio in the secondary effluent biopolyme...

Journal: :Biofouling 2010
Cristina López-Galindo José F Casanueva Enrique Nebot

In an industrial seawater cooling system, the effects of three different antifouling treatments, viz. sodium hypochlorite (NaClO), aliphatic amines (Mexel®432) and UV radiation, on the characteristics of the fouling formed were evaluated. For this study a portable pilot plant, as a side-stream monitoring system and seawater cooling system, was employed. The pilot plant simulated a power plant s...

Journal: :Biofouling 2009
Evan Thomas Dean Muirhead

Capillary dependent systems are highly influenced by surface fouling and may degrade as material surface properties change. In anticipation of a spacecraft microgravity fluids management system exposed to highly variable wetting conditions, the impact of urine wastewater fouling on capillary contact angle was examined. The results indicate that, in general, surface fouling can decrease the cont...

2010
Tomoo Tsuyuhara

Membrane bioreactors (MBRs) have several advantages such as high-quality effluent, small footprint and less sludge production over conventional activated sludge systems, and are therefore considered to be a promising technology for future wastewater treatment. For wider use of MBRs, however, high-energy consumption in the operation of MBRs, mainly attributed to membrane fouling, needs to be add...

Journal: :مهندسی بیوسیستم ایران 0
فخرالدین صالحی دانش آموخته کارشناسی ارشد، دانشگاه فردوسی مشهد سیدمحمدعلی رضوی استاد، دانشکده کشاورزی، دانشگاه فردوسی مشهد مصطفی شهیدی نوقابی دانشجوی دوره دکتری، دانشکده کشاورزی دانشگاه فردوسی مشهد محمد الهی استادیار، دانشکده کشاورزی دانشگاه فردوسی مشهد

the effects of three levels of transmembrane pressure (1.0, 1.5 and 2.0 mpa) as well as three temperature  levels of: 30, 40 and 50°c on the efficiency of nanofiltration process of waste brine from the regeneration of ion exchange resins at sugar industry (to recover water and sodium chloride) were investigated throughout the current study. the polyamide tubular afc40 membrane manufactured by p...

2010
Shenfu Chen Lingyan Li Chao Zhao Jie Zheng

Surface resistance to nonspecific protein adsorption, cell/bacterial adhesion, and biofilm formation is critical for the development and performance of biomedical and analytical devices. Significant needs and efforts have been made in the development of biocompatible and bioactive materials for antifouling surfaces, but much of the work retains an empirical flavor due to the complexity of exper...

Journal: :Water research 2007
Thuy Tran Brian Bolto Stephen Gray Manh Hoang Eddy Ostarcevic

The fouling of a spiral wound reverse osmosis (RO) membrane after nearly 1 year of service in a brackish water treatment plant was investigated using optical and electron microscopic methods, Fourier transform infrared spectroscopy (FTIR) and inductively coupled plasma atomic emission spectrometry (ICP-AES). Both the top surface and the cross-section of the fouled membrane were analysed to moni...

Journal: :Water science and technology : a journal of the International Association on Water Pollution Research 2011
F Y Sun X Y Li

A single-fibre microfiltration system was employed to investigate the importance of various operating and sludge property parameters to the membrane fouling during sludge filtration. The sludge was obtained from a submerged membrane bioreactor (SMBR). A series of comparative and correlative filtration and fouling tests were conducted on the influence of the operating variables, sludge propertie...

2016
Peng Xie Lawrence Murdoch David Ladner

Membrane fouling is a major drawback of reverse osmosis (RO) membrane filtration as it negatively affects the quantity and quality of the permeate and lifespan of the membrane. Spacer plays a pivotal role in hydrodynamics of the membrane channel thus influencing the membrane fouling. In this study, a series of novel sinusoidal spacers that can form unobstructed sinusoidal membrane channels were...