PURPOSE The purpose of the present study was to investigate metabolic changes in different compartments of the rat lens (anterior, nuclear, posterior, and equatorial) after exposure to an acute double threshold dose of ultraviolet-B radiation (UVR-B) by using high-resolution magic angle spinning (HR-MAS) (1)H nuclear magnetic resonance (NMR) spectroscopy and pattern recognition (PR) METHODS: me...
Radiation cataract has been observed at lower doses than previously thought, therefore the annual limit for equivalent dose to eye lens reduced from 150 20 mSv. This study evaluated radiation exposure of operators working in a hybrid operating room before and after implementation reduction program.
The aim of this study was to evaluate radiation dose in patients undergoing three-dimensional rotation angiography (3DRA) and cone-beam computed tomography (CBCT) using a flat panel detector (FPD). Radiation doses were measured for angiography equipment using small silicon-photodiode dosimeters that were implanted in various positions in tissues and organs within an anthropomorphic phantom of a...
The purpose of this paper is to test the appropriateness of OSL and electronic dosemeters to estimate eye lens doses at interventional cardiology environment. Using TLD as reference detectors, personal dose equivalent was measured in phantoms and during clinical procedures. For phantom measurements, OSL dose values resulted in an average difference of -15 % vs. TLD. Tests carried out with other...
Objective- Assessment of the lens anterior – posterior (AP) diameter as compared with the eye globe by ultrasonography in rabbit. Design- Descriptive study. Animals- 120 male and female rabbits, two months to four years old, and weighting between 300 to 1500gr. Procedures- 2D ultrasonography of the eyes was performed and AP diameter of the eyes and lens were measured using Sonosite Tit...
Horn antennas can result in good impedance matching between the waveguide and free space due to the gradual increase in the aperture size. In this paper, a novel plasmonic sectoral horn nanoantenna based on using lens in the aperture is proposed. It is investigated that in addition to improvement of the directivity, the reflection coefficient is also reduced using the proper lens structure. The...
BACKGROUND AND PURPOSE Eye lenses are among the most sensitive organs to x-ray radiation and may be considered at risk during neurointerventional radiology procedures. The threshold dose to produce eye lens opacities has been recently reduced to 500 mGy by the International Commission on Radiologic Protection. In this article, the authors investigated the radiation doses delivered to patients' ...
BACKGROUND The toxic effects of paclitaxel (PTX) on neonatal eyes have not been evaluated. MATERIALS AND METHODS PTX was dissolved in solvent containing polyethoxylated castor oil and intraperitoneally administered to male and female Sprague-Dawley rats at a dose of 0, 2, 4 and 8 mg/kg at 0 day of age, 4 mg/kg at 14 days of age, or 8 mg/kg at 12-18 weeks of age. Eyes were histologically exami...
PURPOSE To compare the dose and image quality of three methods for reducing the radiation dose to the eye at head computed tomography (CT): bismuth shielding, organ-based tube current modulation (TCM), and global reduction of the tube current. MATERIALS AND METHODS An anthropomorphic head phantom was scanned under six conditions: (a) without any dose reduction techniques (reference scanning);...