نتایج جستجو برای: ion chamber dosimetry gamma ray cobalt 60 iec 60731

تعداد نتایج: 951194  

Journal: :Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine 2004
Alan L Nichols

A Co-ordinated Research Project (CRP) was established in 1998 by the IAEA Nuclear Data Section (Update of X-ray and gamma-ray Decay Data Standards for Detector Calibration and Other Applications), in order to improve further the recommended decay data used to undertake efficiency calibrations of gamma-ray detectors. Participants in this CRP reviewed and modified the list of radionuclides most s...

Journal: :Medical physics 1999
P R Almond P J Biggs B M Coursey W F Hanson M S Huq R Nath D W Rogers

A protocol is prescribed for clinical reference dosimetry of external beam radiation therapy using photon beams with nominal energies between 60Co and 50 MV and electron beams with nominal energies between 4 and 50 MeV. The protocol was written by Task Group 51 (TG-51) of the Radiation Therapy Committee of the American Association of Physicists in Medicine (AAPM) and has been formally approved ...

2014
Parvin Mohammadyari Mehdi Zehtabian Sedigheh Sina Ali Reza Tavasoli Reza Faghihi

Currently, the use of blood irradiation for inactivating pathogenic microbes in infected blood products and preventing graft-versus-host disease (GVHD) in immune suppressed patients is greater than ever before. In these systems, dose distribution and uniformity are two important concepts that should be checked. In this study, dosimetry of the gamma chamber blood irradiator model Gammacell 3000 ...

Journal: :International journal of radiation research 2021

Background: This study investigated the γ-rays shielding properties of some building materials in Sudan has been investigated. Materials and Methods: Photons attenuation coefficients half value layer (HVL) were experimented using Cs-137 Co-60 sources. The measurements performed to gauge intensity radiation when unshielded, specific thickness selected samples was examined, an ion chamber placed ...

2016
Lori A. Young Fei Yang Ning Cao Juergen Meyer

During volume-modulated arc therapies (VMAT), dosimetric errors are introduced by multiple open dynamic leaf gaps that are present in fixed diaphragm linear accelerators. The purpose of this work was to develop a methodology for adjusting the rounded leaf end modeling parameters to improve out-of-field dose agreement in SmartArc VMAT treatment plans delivered by fixed jaw linacs where leaf gap ...

1999
Deming Shu P. K. Job Juan Barraza Tim Cundiff Tuncer M. Kuzay

A position-sensitive photoconductive detector (PSPCD) using insulating-type CVD diamond as its substrate material has been developed at the Advanced Photon Source (APS). Several different configurations, including a quadrant pattern for a x-ray-transmitting beam position monitor (TBPM) and 1-D and 2-D arrays for PSPCD beam profilers, have been developed. Tests on different PSPCD devices with hi...

Journal: :Medical physics 2012
Slobodan Devic Nada Tomic Saad Aldelaijan Francois Deblois Jan Seuntjens Maria F Chan Dave Lewis

PURPOSE Despite numerous advantages of radiochromic film dosimeter (high spatial resolution, near tissue equivalence, low energy dependence) to measure a relative dose distribution with film, one needs to first measure an absolute dose (following previously established reference dosimetry protocol) and then convert measured absolute dose values into relative doses. In this work, we present resu...

2016
Robert W. Chuter Philip A. Rixham Steve J. Weston Vivian P. Cosgrove

The feasibility of using portal dosimetry (PD) to verify 6 MV flattening filter-free (FFF) IMRT treatments was investigated. An Elekta Synergy linear accelerator with an Agility collimator capable of delivering FFF beams and a standard iViewGT amorphous silicon (aSi) EPID panel (RID 1640 AL5P) at a fixed SSD of 160 cm were used. Dose rates for FFF beams are up to four times higher than for conv...

Journal: :Radiation Measurements 2023

A pixelated silicon detector, developed originally for particle physics experiments, was used a beam profile measurement of cobalt-60 (Co-60) irradiator in water phantom. The compared to measured with pinpoint ionization chamber. differences the pixel detector and chamber relative profiles were within approximately 2% maximum, after calculating correction factors Monte Carlo simulations maximum...

Journal: :Radiation Oncology (London, England) 2008
G Nicolini E Vanetti A Clivio A Fogliata G Boka L Cozzi

BACKGROUND To report about enhancements introduced in the GLAaS calibration method to convert raw portal imaging images into absolute dose matrices and to report about application of GLAaS to routine radiation tests for linac quality assurance procedures programmes. METHODS Two characteristic effects limiting the general applicability of portal imaging based dosimetry are the over-flattening ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید