نتایج جستجو برای: intermediate moment resisting frame

تعداد نتایج: 291717  

Journal: : 2022

The present study investigates the seismic performance of twelve-story RC buildings focusing on structural effects flat walls which are commonly neglected in design practice. Two-span moment-resisting frame was numerically modeled considering three analytical cases: Case 0 beam-column subassembly, 1 with conventional walls, and 2 damage control were proposed authors’ previous study. Comparing m...

Journal: :journal of rehabilitation in civil engineering 2013
a. habibi k. asadi

setback in elevation of a structure is a special irregularity with considerable effect on its seismic performance. this paper addresses multistory reinforced concrete (rc) frame buildings, regular and irregular in elevation. several multistory reinforced concrete moment resisting frames (rcmrfs) with different types of setbacks, as well as the regular frames in elevation, are designed according...

Journal: :Earthquake Engineering & Structural Dynamics 2022

Abstract Currently, there is no “timber moment frame structural system,” as the basic glulam beam‐to‐column connections (usually represented by bolted with slotted‐in steel plates) offer limited rotational stiffness such that they are usually treated pin connections. This paper proposes an innovative type of moment‐resisting connection reinforced long rods screwheads (LSRSs) and self‐tapping sc...

Journal: :The Bulletin of the Polytechnic Institute of Jassy, Construction. Architecture Section 2021

Abstract M oment R esisting (MR) einforced C oncrete (RC) frame system presented in the current seismic design standards and required to on-site action develops soft storey mechanisms. In practice, idealized theorized ductile response specified for this structural type does not occur. these conditions, research study presents a logical scheme regarding development method of MR RC system. The ma...

Journal: :Buildings 2023

This paper presents quantitative information on the effectiveness of seismic retrofit solutions using bilinear oil dampers for seismically deficient existing tall steel buildings. For this purpose, a benchmark 40-story space moment-resisting frame building is studied that represents 1970s design practice in North America. Rigorous performance assessment based ASCE 41 recommendations reveals hig...

Journal: :The Open Civil Engineering Journal 2017

Journal: :Buildings 2022

In the last two decades, high-rise timber buildings have been built using glulam truss system, even with limited openings. Moment-resisting frames (MRTF) semi-rigid beam-to-column connections can be an architecture-friendly way to provide a load-carrying system vertical and horizontal loads for buildings. these structures, of adequate ductility are crucial ensure robustness energy dissipation. ...

2015
Anna H. Olsen Thomas H. Heaton John F. Hall

This work applies 64,765 simulated seismic ground motions to four models each of 6or 20-story, steel special moment-resisting frame buildings. We consider two vector intensity measures and categorize the building response as “collapsed,” “unrepairable,” or “repairable.” We then propose regression models to predict the building responses from the intensity measures. The best models for “collapse...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید