نتایج جستجو برای: interferometer

تعداد نتایج: 9645  

Journal: :Physical review letters 2010
Tobias Eberle Sebastian Steinlechner Jöran Bauchrowitz Vitus Händchen Henning Vahlbruch Moritz Mehmet Helge Müller-Ebhardt Roman Schnabel

Only a few years ago, it was realized that the zero-area Sagnac interferometer topology is able to perform quantum nondemolition measurements of position changes of a mechanical oscillator. Here, we experimentally show that such an interferometer can also be efficiently enhanced by squeezed light. We achieved a nonclassical sensitivity improvement of up to 8.2 dB, limited by optical loss inside...

Journal: :Applied optics 2009
Jonathan D Ellis Ki-Nam Joo Jo W Spronck Robert H Munnig Schmidt

We describe two different, double-sided interferometer designs for measuring material stability. Both designs are balanced interferometers where the only optical path difference is the sample and the reference beams are located within the interferometer. One interferometer is a double-pass design, whereas the other is a single-pass system. Based on a tolerancing analysis, the single-pass system...

Journal: :Applied optics 2006
Robert M Neal James C Wyant

A new instrument, the polarization phase-shifting point-diffraction interferometer, has been developed by use of a birefringent pinhole plate. The interferometer uses polarization to separate the test and reference beams, interfering what begin as orthogonal polarization states. The instrument is compact, simple to align, and vibration insensitive and can phase shift without moving parts or sep...

2007
E. J. Galvez B. C. Melius

We describe an experiment where the phase and amplitude of the interference pattern of light going through an interferometer was varied by doing operations on quantum-correlated light that did not go through the interferometer. This was accomplished by sending a pair of polarization-entangled photons in separate directions, one to an interferometer and the other one to a phase shifter, in princ...

Journal: :Journal of the Optical Society of America. A, Optics, image science, and vision 2011
Olivier Jacquin Eric Lacot Wilfried Glastre Olivier Hugon Hugues Guillet de Chatellus

Using an Nd:YVO₄ microchip laser with a relaxation frequency in the megahertz range, we have experimentally compared a heterodyne interferometer based on a Michelson configuration with an autodyne interferometer based on the laser optical feedback imaging (LOFI) method regarding their signal-to-noise ratios. In the heterodyne configuration, the beating between the reference beam and the signal ...

2017
Kyunghyun Lee Hyungkwan Kwon Kwanho You

In this paper, we suggest a seismic signal measurement system that uses a laser interferometer. The heterodyne laser interferometer is used as a seismometer due to its high accuracy and robustness. Seismic data measured by the laser interferometer is used to analyze crucial earthquake characteristics. To measure P-S time more precisely, the short time Fourier transform and instantaneous frequen...

Journal: :Applied optics 1999
P P Naulleau K A Goldberg S H Lee C Chang D Attwood J Bokor

The phase-shifting point-diffraction interferometer (PS/PDI) was recently developed and implemented at Lawrence Berkeley National Laboratory to characterize extreme-ultraviolet (EUV) projection optical systems for lithography. Here we quantitatively characterize the accuracy and precision of the PS/PDI. Experimental measurements are compared with theoretical results. Two major classes of errors...

Journal: :IEICE Transactions 2006
Koichi Iiyama Makoto Yasuda Saburo Takamiya

High-resolution FMCW reflectometry is often realized by sampling the beat signal with a clock signal generated from an auxiliary interferometer. The drawback of this system is that the measurement range is limited to less than half of the optical path difference of the auxiliary interferometer to satisfy the Sampling theorem. We propose and demonstrate a method to extend the measurement range o...

Journal: :Applied optics 1996
C R Mercer K Creath

A new instrument, the liquid-crystal point-diffraction interferometer (LCPDI), is developed for the measurement of phase objects. This instrument maintains the compact, robust design of Linnik's point-diffraction interferometer and adds to it a phase-stepping capability for quantitative interferogram analysis. The result is a compact, simple to align, environmentally insensitive interferometer ...

Journal: :Optics letters 1997
K X Sun M M Fejer E K Gustafson R L Byer

We describe a balanced-heterodyne postmodulated Sagnac interferometer signal extraction method that is suitable for gravitational wave detection. The method is simple to implement by placement of a polarization-selective modulator after the beam splitter in the dark port of the interferometer. The postmodulated Sagnac interferometer retains its common path advantage and exhibits insensitivity t...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید