نتایج جستجو برای: i 131 and tc 99m thyroid ornl mird phantom mcnpx

تعداد نتایج: 17085756  

2013
Mauro Boronat Juan J Cabrera Carmen Perera Concepción Isla Francisco J Nóvoa

UNLABELLED A man underwent total thyroidectomy for goiter when he was 62 years old. The pathology report informed on a 5.5 cm oncocytic follicular adenoma and a 3.5 mm papillary microcarcinoma. Due to the papillary tumor, he was treated with ablative radioiodine therapy and suppressive doses of levothyroxine. After uneventful follow-up for 9 years, increased levels of serum thyroglobulin were d...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2011
Dacian V Bonta Raghuveer K Halkar Naomi Alazraki

UNLABELLED After the extravasation of a therapeutic dose of (131)I-metaiodobenzylguanidine that produced a radiation burn to a patient's forearm, we instituted a catheter placement verification protocol. METHODS Before therapy infusion, proper placement is verified by administering 37 MBq of (99m)Tc-pertechnetate through the catheter, and monitoring activity at the administration site and on ...

Armaghan Fard-Esfahani, Behnam Hajian Mohammad Eftekhari, Mohsen Saghari

Differentiated thyroid carcinomas usually show good uptake and response to I-131 ablative treatment. In this study, 90 patients following near total thyroidectomy who were referred to our institute for I-131 therapy are retrospectively studied. The patients are divided in two groups. Group 1 revealed complete ablation after one dose of I-131. Group 2 needed more than one dose of I-131 for...

Journal: :Clinical nuclear medicine 2006
John T Koutsikos Antigone Velidaki Theodoros Athanasoulis

In a 62-year-old man with medullary carcinoma of the thyroid, a postoperative Tc-99m dimercaptosuccinic acid [(V) DMSA] study was requested. In the Tc-99m (V) DMSA scan. no abnormalities, indicating local recurrence or metastatic disease, were observed. However, there was increased uptake in the spleen and liver and significantly diffusely increased uptake in the bone marrow. The patient also h...

F. Atabi, H. Zamani Zeinali, N. Alirezazadeh,

Background: To investigate the status of the nuclear medicine (NM) centers in Iran for the performance of dose calibrators, 18 out of 54 centers providing NM services in Iran were randomly selected and inspected in 1997. In the first phase of the study the selected centers were inspected for performing of quality control (QC) tests of dose calibrators. The linearity of the activity res...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2003
Georg Burggasser Ingrid Hurtl Wolfgang Hauff Julius Lukas Michaela Greifeneder Bamdad Heydari Arnulf Thaler Andreas Wedrich Irene Virgolini

UNLABELLED Receptors for somatostatin (SST) (SSTR) are expressed on various tumor cells as well as on activated lymphocytes. Previous data have shown that (99m)Tc-P829 binds with high affinity to many different types of tumor cells as well as to leukocytes via the human hSSTR2, hSSTR3, and hSSTR5 target receptors. Consequently, (99m)Tc-P829 was successfully introduced as a peptide tracer for tu...

Journal: :Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association 1999
R Martínez-Lázaro A Cortés

Key words: hyperparathyroidism-radionuclide-imaging; primary and secondary hyperparathyroidism [1–3]. With hyperplastic parathyroid glands tetrofosmin hyperplasia; Technetium-99m-diagnostic use; tetrofosmin imaging gives an overall sensitivity of 84% and a specificity of 75%, higher than those of Tc-99m sestam-ibi, ultrasonography and magnetic resonance imaging Renal history [1–2]. The former h...

Journal: :Japanese Journal of Radiological Technology 1996

2011
Jan T. M. JANSEN

The general-purpose Monte Carlo radiation transport code MCNPX has been used to simulate photon transport and energy deposition in anthropomorphic phantoms due to the x-ray exposure from the Philips iCT 256 and Siemens Definition CT scanners, together with the previously studied General Electric 9800. The MCNPX code was compiled with the Intel FORTRAN compiler and run on a Linux PC cluster. A p...

Journal: :iranian journal of radiation research 0
h. zamani zeinali faculty of nuclear engineering and physics, amir kabir university of technology, tehran, iran n. alirezazadeh national radiation protection department, atomic energy organization of iran f. atabi department of medical biochemistry, isfahan university of medical sciences, isfahan, iran

background: to investigate the status of the nuclear medicine (nm) centers in iran for the performance of dose calibrators, 18 out of 54 centers providing nm services in iran were randomly selected and inspected in 1997. in the first phase of the study the selected centers were inspected for performing of quality control (qc) tests of dose calibrators. the linearity of the activity response, pr...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید