نتایج جستجو برای: hplc assay

تعداد نتایج: 250926  

Journal: :Artificial cells, blood substitutes, and immobilization biotechnology 2005
Zhiquan Zhao Yong Sun Qiqing Zhang Jun Jiang

This paper reports a RP-HPLC method for the determination of Lomustine (CCNU) in mouse tumor tissue. CCNU was separated and determined on a reverse-phase C18 5 microm column with a mobile phase of H2O-acetonitrile (54:46), detected at 254 nm and no internal standard. The calibration curve was linear (r = 0.9999) within the range of 0.98-15.68 microg/ml for CCNU. The recovery ratio of CCNU was 6...

2010
Matteo Mozzicafreddo Massimiliano Cuccioloni Anna Maria Eleuteri Mauro Angeletti

Radioisotope-based and mass spectrometry coupled to chromatographic techniques are the conventional methods for monitoring HMG-CoA reductase (HMGR) activity. Irrespective of offering adequate sensitivity, these methods are often cumbersome and time-consuming, requiring the handling of radiolabeled chemicals or elaborate ad-hoc derivatizing procedures. We propose a rapid and versatile RP-HPLC me...

Journal: :Clinical chemistry 1997
K Kuo R Still S Cale I McDowell

Measurement of plasma homocysteine may be of value in several clinical conditions including homocystinuria, ath-erosclerosis, thrombophilia, and folate/vitamin B 12 deficiency. The increasing interest in measuring total homo-cysteine in plasma has led to the development of several different methods [1]. A widely used technique for measuring total plasma homocysteine is reversed-phase HPLC with ...

2009
V. R. Sinha R. V. Kumar J. R. Bhinge

The present study describes the development of a validated RP-HPLC method for the determination of 5-fluorouracil in presence of its degradation products or other pharmaceutical excipients. Stress studies were performed on 5-fluorouracil and it was found that it degrades sufficiently in alkaline conditions, while negligible degradation was observed in acidic, neutral, oxidative and photolytic c...

Journal: :Biomedical chromatography : BMC 2008
R Espada J M Josa S Valdespina M A Dea M P Ballesteros J M Alunda J J Torrado

A fast and selective HPLC method for assaying amphotericin B in biological samples was developed and validated. The chromatographic separation was achieved in less than 12 min on a reverse-phase C(18) column using an acetonitrile-acetic acid-water (52:4.3:43.7, v/v/v) mixture as mobile phase. The flow rate was 1 mL/min and the effluent was monitored at 406 nm. A linear response over the concent...

2013
Deepti Jain Rajiv Gandhi P. K. Basniwal S. Panda S. Jain

A sensitive, stability-indicating liquid-chromatographic method for analysis of tamsulosin in the presence of its degradation products has been developed and validated. Efficient chromatographic separation was achieved on a C18 column with a simple isocratic mobile phase consisting methanol: 50 mM phosphate buffer (pH 7.8, ratio 80:20) at a flow rate of 1 ml/m. The linearity of the method was e...

Journal: :Clinical biochemistry 2008
Limin Liu Stefanie Hood Yuping Wang Robert Bezverkov Chao Dou Abhijit Datta Chong Yuan

OBJECTIVES Development and validation of a direct enzymatic HbA1c assay that utilizes a single channel on chemistry auto-analyzers without the need to run separate glycated hemoglobin and total hemoglobin assays. DESIGN AND METHODS An enzyme based single channel assay was developed to measure %HbA1c in human whole blood samples. The performance characteristics of the Diazyme Direct Enzymatic ...

2015
Raphael Reuter Thomas R Ward

Herein we report on a 96-well plate assay based on the fluorescence resulting from the ring-closing metathesis of two profluorophoric substrates. To demonstrate the validity of the approach, four commercially available ruthenium-metathesis catalysts were evaluated in six different solvents. The results from the fluorescent assay agree well with HPLC conversions, validating the usefulness of the...

2007
K. F. Yeung Carrie Ferguson Ameer Jarrar Brian King Mary L. Li

Purpose: To develop and validate a sensitive and specific HPLC assay for cladribine (CdA) in plasma for pharmacokinetic studies in rats. Methods: CdA and the internal standard AZT were purchased from Sigma-Aldrich Chem. The HPLC system consisted of a Shimadzu LC-9A pump, a 3 μm, 250 x 2.0 mm I.D. high speed C18 column (Jupiter), preceded by a 5 μm 4 x 4 mm I.D. C18 guard column (Licrocart), an ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید