نتایج جستجو برای: heterogeneous slab phantom

تعداد نتایج: 152537  

2015
Aurélien J Trotier Charles Castets William Lefrançois Jean-Michel Franconi Eric Thiaudière Sylvain Miraux

Background Time resolved phase contrast imaging is hardly used in small animal studies due to a lack of signal-to-noise ratio. Some studies were performed in 2D and one publication (Janiczek et al, MRM 2011) reported flow measurement in mouse aortic arch in 3D due to the use of a thin excitation slab and high Time-Of-Flight (TOF) effect. However, this strategy is not applicable on the whole car...

Journal: :Journal of cancer research and therapeutics 2013
Allahverdi Mahmoud Nourollahi Somayeh Esfahani Mahbod Aghili Mehdi Changizi Vahid Geraily Ghazale

AIM Complex geometry of breast tissue causes perturbation in dose distribution. This problem can beget overdose or under-dose points in match region of three fields. The aim of this study is to create dose homogeneity distribution in match region between tangential and supraclavicular fields (SCF) with Gafchromic external beam therapy (EBT) film. MATERIALS AND METHODS In this study, an anatom...

Journal: :Medical physics 2016
N Lamichhane M Studenski

PURPOSE It is essential to assess the lung dose during TBI to reduce toxicity. Here we characterize the accuracy of the AAA and Acuros algorithms when using cerrobend lung shielding blocks at an extended distance for TBI. METHODS We positioned a 30×30×30 cm3 solid water slab phantom at 400 cm SSD and measured PDDs (Exradin A12 and PTW parallel plate ion chambers). A 2 cm thick, 10×10 cm2 cerr...

This study presents the results of an experimental program to investigate the effectiveness of an innovative combined FRP technique using combination of externally bonded (EB) FRP fabrics and near surface mounted (NSM) FRP rods for flexural strengthening of existing reinforced concrete (RC) two-wayslabs with low clear cover thickness. Three full-scale RC slabs (1500×1500×120 mm) were tested und...

2003
Nzhde Agazaryan Timothy D. Solberg John J. DeMarco

A patient specific quality assurance program has been developed to facilitate the clinical implementation of intensity modulated radiotherapy (IMRT) delivered using a micro-multileaf collimator. The methodology includes several dosimetric tasks that are performed prior to the treatment of each patient. Film dosimetry is performed for each individual field and for the multifield composite plan. ...

2013
Suresh Rana Kevin Rogers Shyam Pokharel Terry Daniel Reed Christopher Biggs

Our purpose in this study was to assess the dosimetric impact of the Acuros XB algorithm (AXB), in comparison with Anisotropic Analytical Algorithm (AAA) calculations, for esophageal cancer treatment plans created with RapidArc technique. First, we performed a phantom study by comparing the percent depth dose (PDD) calculated by AXB and AAA against the measured PDD in a slab phantom containing ...

Journal: :journal of biomedical physics and engineering 0
s a rahimi tarbiat modares university b hashemi tarbiat modares university s r mahdavi iran university of medical sciences

background: estimating dosimetric parameters for small fields under non-reference conditions leads to significant errors if done based on conventional protocols used for large fields in reference conditions. hence, further correction factors have been introduced to take into account the influence of spectral quality changes when various detectors are used in non-reference conditions at differen...

Seyed Mohammad Mahdi Abtahi Vahid Anaraki

Introduction: Three physical conditions caused an external beam designated as a small field. The first is the loss of lateral charged particle equilibrium. The second is the effect of collimators on the primary photon source occlusion. The third condition is the size of the detector which is large compared to the field size. The most obvious perturbation effects in last condit...

2013
Xiaodong Liu Danielle Lack Joseph T. Rakowski Cory Knill Michael Snyder

Our institution delivers TBI using a modified Theratron 780 60Co unit. Due to limitations of our treatment planning system in calculating dose for this treatment, we have developed a fast Monte Carlo code to calculate dose distributions within the patient. The algorithm is written in C and uses voxel density information from CT images to calculate dose in heterogeneous media. To test the algori...

2004
José A. Bencomo Connel Chu Victor M. Tello Sang Hyun Cho Geoffrey S. Ibbott

An evaluation of two anthropomorphic breast phantoms, which have been designed for quality assurance and dose verification of radiotherapy treatment of breast cancer patients, is presented. These phantoms are identical in terms of their dimensions and shape, and composed of several layers of either Plastic Water or tissue-equivalent material. Both water- and tissue-equivalent phantoms include l...

نمودار تعداد نتایج جستجو در هر سال