Purpose: To study and compare the dose response curves of the new GafChromic EBT3 film for megavoltage and kilovoltage x-ray beams, with different spatial resolutions. Methods: EBT3 films (lot#A101711-02) were exposed to each x-ray beam (6 MV, 15 MV, and 50 kV) at 7 dose values (50 3200 cGy). Each film piece was scanned three consecutive times in the center of Epson 10000XL flatbed scanner in 4...
PURPOSE The purpose of this study was to measure the dose distributions for different Radiation Oncology Physics and Engineering Services, Australia (ROPES) type eye plaques loaded with I-125 (model 6711) seeds using GafChromic(®) EBT3 films, in order to verify the dose distributions in the Plaque Simulator™ (PS) ophthalmic 3D treatment planning system. The brachytherapy module of RADCALC(®) wa...
PURPOSE To establish a film dosimetric method for high-resolution measurement in the dose build-up region. METHODS Percent depth dose (PDD) curves were measured in water for TomoTherapy using Gafchromic EBT2 films. Depth dose measurements were also performed using Standard Imaging A1SL and PTW PinPoint ionization chambers, as well as a PTW DiodeE detector. The film and detector measurements w...
The Monte Carlo technique and GafChromic films were employed to verify the accuracy of the dose planning system (Leksell GammaPlan) used in Gamma Knife (type B) radiosurgery when plugged collimator helmets were used. The EGS4 Monte Carlo code was used to calculate the dose distribution along the x, y, and z axes when a single shot was delivered at the center point (unit center point: x = 100, y...
OBJECTIVES To implement a new cost efficacy internal Service for blood component irradiation, we carried out specific procedures and quality assurance reports using the linear accelerators (LINACs) of the Regina Elena Institute (IRE) Radiotherapy Department instead of a dedicated device. METHODS The technical aspects, quality assurance and regulatory requirements of the internal procedure to ...
The purpose of this study was to evaluate a single-scan protocol using Gafchromic EBT3 film (EBT3) by comparing it with the commonly used 24-hr measurement protocol for radiochromic film dosimetry. Radiochromic film is generally scanned 24 hr after film exposure (24-hr protocol). The single-scan protocol enables measurement results within a short time using only the verification film, one calib...
In the present study, a series of experiments were performed to study collisions runaway electrons in Damavand tokamak by imaging hard x-ray radiations, as one secondary effects these electrons, using radiochromic films. For experiments, GAFCHROMIC™EBT2 dosimetry films selected due their high resolution capability. These instruments installed two strip and screen structures for one- two-dimensi...
Dose distribution verification for GYN brachytherapy using EBT Gafchromic film and TG-43 calculation