نتایج جستجو برای: film dosimeter

تعداد نتایج: 92845  

2010
Cheng-Shie Wuu

Both polymer gels and PRESAGE radiochromic solid dosimeter, in conjunction with optical CT scanning system, have been employed to measure 3-D dose distribution. The 3-D dose maps obtained from these systems can provide a useful tool for dose verification on complex treatments such as IMRT, radiosurgery, and RapidArc. These complex treatments present high dose gradient regions in the boundaries ...

2007
D. J. Turnbull P. W. Schouten

Exposure to UV radiation is known to be a causative factor in the induction of skin cancers and other sun-related disorders. Most acute responses of humans to UV exposure occur as a result of UVB (280 to 315 nm) exposures, as these wavelengths are highly sensitive in creating a human biological response. However, this does not mean that UVA radiation has no impact on human UV exposures and heal...

2016
Kam Shan Mong Anthony B. Wallace Rick D. Franich

The purpose of this study was to demonstrate asymmetric radiation dose distribution to the breasts in coronary angiography. Gafchromic XR-QA2 film was used as an area dosimeter to capture the asymmetric dose distribution to the breasts at various tissue depths in an anthropomorphic phantom. A selection of tube angulations were used under a controlled experiment and during a mock coronary angiog...

2006
Mohammad Mohammadi Eva Bezak Paul Reich

A scanning liquid-filled ionization chamber electronic portal imaging device (SLIC-EPID) and extended dose range (EDR2) films were used to evaluate transmitted dose profiles for homogeneous and inhomogeneous phantoms. Calibrated ionization chamber measurements were used to convert the pixel values acquired from the electronic portal images to dose. Because SLIC-EPID was developed to have a unif...

2008
G. SARRABAYROUSE S. SISKOS

-The influence of the irradiation dose on the parameters which control the temperature sensitivity of thick oxide p-MOS ionising radiation dosimeters is investigated. The temperature sensitivity of the threshold voltage, the carrier mobility and the minimum temperature coefficient current appear to be dose-dependent contrary to what is generally considered. The consequences on the dose measurem...

Journal: :Medical dosimetry : official journal of the American Association of Medical Dosimetrists 2012
Matthew T Studenski Ying Xiao Amy S Harrison

Recently in our clinic, we have seen an increased number of patients presenting with pacemakers and defibrillators. Precautions are taken to develop a treatment plan that minimizes the dose to the pacemaker because of the adverse effects of radiation on the electronics. Here we analyze different dosimeters to determine which is the most accurate in measuring pacemaker or defibrillator dose whil...

2008
Ridthee Meesat Jean-Paul Jay-Gerin Abdelouahed Khalil Martin Lepage

In this study, our aim is to assess the potential of Fricke and polyacrylamide gel (PAG) dosimeters to quantitatively evaluate the efficiency of potential radiation sensitizers/protectors and antioxidants. These compounds are of importance in radiotherapy as well as in disease prevention and promotion of health. The basic principle of the Fricke dosimeter is the radiation-induced oxidation of F...

2013
Alberto Boriano Francesco Lucio Elisa Calamia Elvio Russi Flavio Marchetto

When using an electronic portal imaging device (EPID) for dosimetric verifications, the calibration of the sensitive area is of paramount importance. Two calibration methods are generally adopted: one, empirical, based on an external reference dosimeter or on multiple narrow beam irradiations, and one based on the EPID response simulation. In this paper we present an alternative approach based ...

2014
Wook Jae Yoo Sang Hun Shin Dayeong Jeon Seunghan Hong Hyeok In Sim Seon Geun Kim Kyoung Won Jang Seunghyun Cho Won Sik Youn Bongsoo Lee

A miniature fiber-optic dosimeter (FOD) system was fabricated using a plastic scintillating fiber, a plastic optical fiber, and a multi-pixel photon counter to measure real-time entrance surface dose (ESD) during radiation diagnosis. Under varying exposure parameters of a digital radiography (DR) system, we measured the scintillating light related to the ESD using the sensing probe of the FOD, ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید