نتایج جستجو برای: dynamic hip screw

تعداد نتایج: 481208  

Journal: :Journal of orthopaedic surgery 2007
T C Wong S H Yeung F K Ip

PURPOSE To compare the results of screw fixation plus capsular decompression versus screw fixation alone for managing intracapsular hip fractures. METHODS Of 201 patients with intracapsular hip fractures, 99 underwent screw fixation with capsular decompression (capsular decompression group) and 102 underwent screw fixation alone (control group). The incidence and time to development of avascu...

Journal: :British Journal of Surgery 2021

Abstract Aim The treatment of impacted or un-displaced femoral neck fractures in the elderly osteoporotic patient is still largely debated, with arthroplasty versus internal fixation two surgical options1. Our aim was to retrospectively review patients over age 80 intracapsular hip who had undergone and assess their rate mortality revision surgery. Method We conducted a retrospective all 4-year...

Journal: :International Journal of Orthopaedics Sciences 2023

Background: The angle between femur neck and the long axis of shaft is known as which plays vital role in stability, control lateral balance, walking hip movements. main goal was to compare NSA intertrochanteric fracture immediately after surgical fixation using either Dynamic Hip Screw or Proximal Femoral Nail. In elderly among all fractures approximately half are out 50% unstable.Method: X-ra...

Journal: :Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca 2016
S Lidder B Hylton A Nahhas S Rajaratnam A Skymre A Armitage

UNLABELLED PURPOSE OF THE STUDY The aim of this prospective study; The Trauma Assisted Discharge Scheme (TADS), was to set up a new model of postoperative care for patients following a fractured hip, addressing the need for efficiency, cost effectiveness and meeting local demand. MATERIAL AND METHODS All patients with hip fractures between December 2010 and December 2011, meeting the TADS inclu...

2014
Nikolaos Patelis Andreas Koutsoumpelis Konstantinos Papoutsis George Kouvelos Chrysovalantis Vergadis Anastasios Mourikis Sotiris E. Georgopoulos

Pseudoaneurysms and hemorrhage of the profunda femoris artery (PFA) are rare injuries and have been reported following trauma or orthopedic procedures performed in the proximal femur [1–4]. Pseudoaneurysms or hemorrhage of the PFA following dynamic hip screw fixation (DHS) for an intertrochanteric femoral fracture constitutes 0.2% of all PFA injury cases [5]. Presentation may be acute or delaye...

Journal: :Injury 2006
G Z Said O Farouk A El-Sayed H G Said

Twenty-six patients with failed dynamic hip screw fixation of intertrochanteric fractures were included in this study. The mean age of the patients was 61 years (range, 38-84 years). Average limb shortening was 2.4 cm; 18 patients were treated with revision internal fixation and eight patients with prosthetic replacement. The decision depended on the physiological age of the patient, quality of...

2012

The Tip Apex Distance (TAD) is a simple measurement that predicts screw cut-out in the femoral head from trochanteric fractures treated with a fixed angle sliding hip screw device [1]. It uses a numerical value to show placement of the screw in the head: higher values indicating higher likelihood of fixation failure by extrusion of the screw. Currently the cost of hip fracture care in the UK is...

2013
Andrej N Nikoloski Anthony L Osbrough Piers J Yates

BACKGROUND Unstable proximal femoral fractures are common and challenging for the orthopaedic surgeon. Often, these are treated with intramedullary nails. The most common mode of failure of any device to treat these fractures is cut-out. The Synthes proximal femoral nail antirotation (PFNA) is unique because it is the only proximal femoral intramedullary nail which employs a helical blade in li...

2006
Zaka Ullah Khan Javaid Iqbal Selvaraj Aravindan

Objective: The aim of this study was two fold. To determine the diagnostic reference level (D.R.L.) dose of radiation during dynamic hip screw (D.H.S.) fixation and, to audit the orthopaedic department against this standard. Methods and Materials: A retrospective analysis of 112 consecutive patients between 31st December 2002 and the 6th July 2003, at Darenth Valley Hospital, Dartford, under go...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید