Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 1999
J A Siegel S R Thomas J B Stubbs M G Stabin M T Hays K F Koral J S Robertson R W Howell B W Wessels D R Fisher D A Weber A B Brill

This report describes recommended techniques for radiopharmaceutical biodistribution data acquisition and analysis in human subjects to estimate radiation absorbed dose using the Medical Internal Radiation Dose (MIRD) schema. The document has been prepared in a format to address two audiences: individuals with a primary interest in designing clinical trials who are not experts in dosimetry and ...

Journal: :Medical physics 2004
Hugo Bouchard Jan Seuntjens

The present paper addresses reference dose measurements using thimble ionization chambers for quality assurance in IMRT fields. In these radiation fields, detector fluence perturbation effects invalidate the application of open-field dosimetry protocol data for the derivation of absorbed dose to water from ionization chamber measurements. We define a correction factor C(Q)IMRT to correct the ab...

Journal: :Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics 2018
Elisa Grassi Federica Fioroni Salvatore Berenato Nick Patterson Valentina Ferri Luca Braglia Angelina Filice Annibale Versari Mauro Iori Emiliano Spezi

Peptide receptor radionuclide therapy (PRRT) is an effective MRT (molecular radiotherapy) treatment, which consists of multiple administrations of a radiopharmaceutical labelled with 177Lu or 90Y. Through sequential functional imaging a patient specific 3D dosimetry can be derived. Multiple scans should be previously co-registered to allow accurate absorbed dose calculations. The purpose of thi...

2014
Antony L Palmer David Bradley Andrew Nisbet

The measurement of dose distributions in clinical brachytherapy, for the purpose of quality control, commissioning or dosimetric audit, is challenging and requires development. Radiochromic film dosimetry with a commercial flatbed scanner may be suitable, but careful methodologies are required to control various sources of uncertainty. Triple-channel dosimetry has recently been utilized in exte...

2018
Huagang Yan Fanqing Guo Dengsong Zhu Stefan Stryker Sharron Trumpore Kenneth Roberts Susan Higgins Ravinder Nath Zhe Chen Wu Liu

Special attention is required in planning and administering radiation therapy to patients with cardiac implantable electronic devices (CIEDs), such as pacemaker and defibrillator. The range of dose to CIEDs that can induce malfunction is large among CIEDs. Clinically significant defects have been reported at dose as low as 0.15 Gy. Therefore, accurate estimation of dose to CIED and dose reducti...

2012
Satish C. Uniyal Umesh C. Naithani Sunil D. Sharma Anoop K. Srivastava

Heterogeneities existing in the patient during treatment are neglected, as the treated subject is considered homogeneous in most of the commercially-available treatment planning systems (TPSs) used for high dose rate (HDR) brachytherapy. The choice of a suitable dosimeter for experimental dosimetry near the HDR source is crucial, mainly due to existence of steep dose gradients. The present work...