نتایج جستجو برای: detector size

تعداد نتایج: 610639  

2008
V. Boccone

ArDM is a new-generation WIMP detector which will measure simultaneously light and charge from scintillation and ionization of liquid argon. Our goal is to construct, characterize and operate a 1 ton liquid argon underground detector. The project relies on the possibility to extract the electrons produced by ionization from the liquid into the gas phase of the detector, to amplify and read out ...

2007
Dianna D. Cody

Cardiac imaging with multiple-row detector computed tomography (CT) has become possible due to rapid advances in CT technologies. Images with high temporal and spatial resolution can be obtained with multiple-row detector CT scanners; however, the radiation dose associated with cardiac imaging is high. Understanding the physics of cardiac imaging with multiple-row detector CT scanners allows op...

Journal: :Journal of biomedical optics 2009
Manojit Pramanik Geng Ku Lihong V Wang

We developed a novel concept of using a negative acoustic lens to increase the acceptance angle of an unfocused large-area ultrasonic transducer (detector), leading to more than twofold improvement of the tangential resolution in both thermoacoustic and photoacoustic tomography. In both thermoacoustic and photoacoustic tomography, for a given transducer bandwidth, the aperture size of the detec...

1987
N. E. IPE D. D. BUSICK

The BD-100 is a neutron bubble detector which is available commercially from Chalk River Nuclear Laboratories, Canada. The detector consists of tiny superheated liquid droplets that are dispersed throughout a firm elastic polymer. The polymer is contained in a small capped and sealed glass (glass detector) or plastic (plastic detector) test tube. A low boiling point liquid floating above the po...

2000
Yeunggyu Park Hoonju Yun Myongseop Song Jaihie Kim

In this paper, we propose a fast circular edge detector for the iris region segmentation by detecting the inner and outer boundaries of the iris. In previous work, the circular edge detector which John G.Daugman proposed, searches the radius and the center of the iris to detect its outer boundary over an eye image. To do so, he used Gaussian filter to smooth texture patterns of the iris which c...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2008
Yongfeng Yang Yibao Wu Jinyi Qi Sara St James Huini Du Purushottam A Dokhale Kanai S Shah Richard Farrell Simon R Cherry

UNLABELLED Detectors with depth-encoding allow a PET scanner to simultaneously achieve high sensitivity and high spatial resolution. METHODS A prototype PET scanner, consisting of depth-encoding detectors constructed by dual-ended readout of lutetium oxyorthosilicate (LSO) arrays with 2 position-sensitive avalanche photodiodes (PSAPDs), was developed. The scanner comprised 2 detector plates, ...

2014
Magdalena Herbst Frank Schebesch Martin Berger Rebecca Fahrig Joachim Hornegger Andreas Maier

In C-arm computed tomography, the field of view (FOV) is often not sufficient to acquire certain anatomical structures, e.g. a full hip or thorax. Recently proposed methods to extend the FOV use a fixed detector displacement and a 360◦ scan range to double the radius of the FOV. These trajectories are designed for circular FOVs. However, there are cases in which the required FOV is not circular...

2003
Craig S. Levin

Certain gamma ray and positron emitting radiotracers have shown great promise for use in the detection, diagnosis and staging of breast cancer. Unfortunately, standard nuclear emission cameras (SPECT, PET) found in the clinic are not practical for breast imaging of these emissions due to inadequate spatial and energy resolutions and sensitivity, large and awkward size, and relatively high cost ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید