نتایج جستجو برای: corneal parameters

تعداد نتایج: 605469  

Journal: :بینا 0
محمد اعتضاد رضوی m etezad-razavi مشهد- بلوار شهید قره نی- بیمارستان فوق تخصصی و مرکز تحقیقات چشم پزشکی خاتم الانبیا (ص) مهرداد حفاظی m hefazi مشهد- بلوار شهید قره نی- بیمارستان فوق تخصصی و مرکز تحقیقات چشم پزشکی خاتم الانبیا (ص) محمود محمودی m mahmoudi مشهد- بلوار شهید قره نی- بیمارستان فوق تخصصی و مرکز تحقیقات چشم پزشکی خاتم الانبیا (ص) مهدی بلالی مود m balali-mood مشهد- بلوار شهید قره نی- بیمارستان فوق تخصصی و مرکز تحقیقات چشم پزشکی خاتم الانبیا (ص)

purpose: to determine any possible correlation between delayed ocular complications with late-onset complications of mustard gas poisoning in other systems including skin, respiratory tract, and immunohematologic system. methods: the study was conducted on 40 chemical war victims in khorasan province, iran. ophthalmologic and dermatologic examinations and spirometry were performed for all patie...

A. A. Sarchahi, A. Meimandi Parizi M. A. Gholipour M. Eghtedari

The purpose of this study was to evaluate the effects of different time combinations of dexamethasoneand acetylcysteine on experimentally induced corneal ulcers in dogs. Experimental corneal wounds werecreated surgically to the anterior one third of the cornea in the center of all eyes of 15 mixed breed dogs. The eyes were divided into five groups according to planned post-operative medications...

Journal: :journal of current ophthalmology 0
محمدناصر هاشمیان mohammad-nasser hashemian فیروزه رحیمی firouzeh rahimi بابک دهسروی babak dehsarvi ساسان مقیمی sasan moghimi سیدمحمد میرآفتاب seyed-mohammad miraftab

purpose: to study the effect of phototherapeutic keratectomy (ptk) in the treatment of various superficial corneal pathologies. methods: we performed a nonrandomized, prospective study on patients who presented with superficial corneal disease and/or poor vision. fifty eyes were included recurrent corneal erosion (rce): 25 eyes, salzmann’s nodular degeneration: 9 eyes, spheroidal degeneration: ...

Journal: :journal of current ophthalmology 0
محمدعلی زارع mohammad-ali zare محمدطاهر رجبی mohammad-taher rajabi

purpose: congenital corneal leukoma is rare with an incidence of 6/100000 and is one of the most important causes of amblyopia. here we report an unusual case of bilateral congenital elevated corneal leukoma. methods: we encountered a 13-day-old full term male newborn. ocular examination of both eyes revealed central elevated corneal leukomas with a narrow normal lucid interval to limbus. corne...

2017
Kazunori Hirasawa Masato Matsuura Hiroshi Murata Shunsuke Nakakura Yoshitaka Nakao Yoshiaki Kiuchi Ryo Asaoka

PURPOSE To investigate the association between corneal biomechanical properties measured with the Ocular Response Analyzer (ORA) and also CorvisST (CST) tonometry, and glaucomatous visual field (VF) severity. METHODS One hundred forty-six eyes of 91 patients with primary open-angle glaucoma who performed Humphrey Field Analyzer 30-2 or 24-2 SITA-Standard, ORA, and CST within 180 days were inc...

Journal: :Archivos de la Sociedad Espanola de Oftalmologia 2008
M J Giráldez-Fernández A Díaz-Rey C García-Resua E Yebra-Pimentel-Vilar

OBJECTIVE Corneal topography and thickness has clinical importance in contact lens fitting and refractive surgery, however repeated measurement of corneal thickness and curvature is complicated by the natural phenomenon of diurnal variation. Our aim was determine diurnal variations of central and paracentral corneal thickness and curvature over a period of ten hours. MATERIALS AND METHODS Cor...

Journal: :International journal of ophthalmology 2014
Ziad Hassan Laszlo Modis Eszter Szalai Andras Berta Gabor Nemeth

AIM To compare the anterior and posterior corneal parameters before and after collagen cross-linking therapy for keratoconus. METHODS Collagen cross-linking was performed in 31 eyes of 31 keratoconus patients (mean age 30.6±8.9y). Prior to treatment and an average 7mo after therapy, Scheimpflug analysis was performed using Pentacam HR. In addition to corneal thickness assessments, corneal rad...

2017
Qamar Ul Islam Mohammad Asim Mehboob Zulfiqar Ali Amin

Objective To compare corneal morphological parameters between diabetics and age matched non-diabetic control subjects and to evaluate the correlation of these parameters in relation to duration of diabetes mellitus (DM), glycemic status and severity of diabetic retinopathy.(DR). Methods This cross sectional comparative study was conducted at the Department of Ophthalmology, PNS Shifa Karachi ...

2016
Nandor Bekesi Carlos Dorronsoro Andrés de la Hoz Susana Marcos

OBJECTIVE To validate a new method for reconstructing corneal biomechanical properties from air puff corneal deformation images using hydrogel polymer model corneas and porcine corneas. METHODS Air puff deformation imaging was performed on model eyes with artificial corneas made out of three different hydrogel materials with three different thicknesses and on porcine eyes, at constant intraoc...

2013
Bashirah Ishak Jacyln JiaYing Thye Bariah Mohd Ali Norhani Mohidin

Background Contact lens (CL) wear can cause changes in blinking and corneal staining. Aims and Objectives To determine the effects of CL materials (HEMA and SiHy) on spontaneous blink rate, blinking patterns and corneal staining after 2 months of wear. Methods Ninety subjects in 3 groups (control, HEMA and SiHy) were assessed at baseline and 2-months. Blink rate was recorded using a video camer...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید