نتایج جستجو برای: contrast scan

تعداد نتایج: 465873  

2014

Image contrast in CT is mostly dependent on elements with high atomic weight, such as calcium, iron, and iodine The concentrations of these elements can be calculated from dual-energy x-ray data based on their characteristic attenuation patterns Dual-energy CT may can be helpful in neuroimaging to: Differentiate between hemorrhage and iodinated contrast agents in brain parenchyma Improve CT ang...

2016
Luca Saba Michele Anzidei Carlo Nicola de Cecco Michele Porcu Antonella Balestrieri Roberto Sanfilippo Marco Francone Alessio Mereu Pierleone Lucatelli Roberto Montisci Jasjit S. Suri Max Wintermark

Background: In the CT assessment of the carotid plaque, the analysis of the attenuation value is a fundamental parameter in order to classify the type of the tissue that composes the plaque. The purpose of this paper is to assess the intra-plaque attenuation variability in order to verify the potential reproducibility of HU measurements. Methods: In this retrospective study, 68 consecutive pati...

Journal: :Journal of radiology case reports 2010
Nidhi Gupta Achim Schwenk Rudi Borgstein

We present a 39-year old man with mesenteric ischaemia. The initial unenhanced images of the, non-oral contrast CT abdomen clearly demonstrated increased density in a significant length of the small bowel and in the veins of the adjacent mesentery. Mesenteric ischaemia is a difficult diagnosis both clinically and radiologically and we demonstrate the potential benefits of an unenhanced abdomina...

2001
F.T.A.W. Wajer M. Fuderer J. van den Brink D. van Ormondt R. de Beer

Contrast enhanced magnetic resonance angiography enables one to visualize the vascular system of the human body. Typically, using conventional measurement techniques, one three-dimensional volume of the vascular system can be measured during the passage of the contrast agent. More recently, medical doctors desire time-information of the blood-flow, or want to scan time-dependent phenomena. To e...

Journal: :Nihon Hoshasen Gijutsu Gakkai zasshi 2007
Takaaki Kitai Takesi Ogawa Jun Noguti Muneyosi Hara Hitosi Otuka Fumiaki Yamamoto Satosi Kawakami Hiroki Yamada

Negative product value for coronary artery disease is 98% to 99%. Therefore, the number of unnecessary cardiac catheterization procedures is reduced as the usefulness of CT systems for examination of the coronary arteries improves. In the bolus-tracking method, in which an ROI is placed in the ascending aorta to trigger scanning, scanning may not be performed at the optimal time of contrast enh...

Journal: :AJNR. American journal of neuroradiology 1990
G Sze E Milano C Johnson L Heier

Contrast-enhanced MR studies were compared with noncontrast MR and contrast-enhanced CT scans in the evaluation of intraparenchymal brain metastases. Fifty consecutive inpatients were studied with short and long repetition time (TR) sequences before and after the administration of gadopentetate dimeglumine. In addition, a delayed short TR sequence was performed. The contrast CT, noncontrast MR,...

Journal: :Dento maxillo facial radiology 2015
D Chambers R Bohay L Kaci R Barnett J Battista

OBJECTIVES To determine the effective dose and CT dose index (CTDI) for a range of imaging protocols using the Sirona GALILEOS(®) Comfort CBCT scanner (Sirona Dental Systems GmbH, Bensheim, Germany). METHODS Calibrated optically stimulated luminescence dosemeters were placed at 26 sites in the head and neck of a modified RANDO(®) phantom (The Phantom Laboratory, Greenwich, NY). Effective dose...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید