نتایج جستجو برای: contact nominal pressure

تعداد نتایج: 589453  

Journal: :Journal of biomechanics 2003
Benjamin J Fregly W Gregory Sawyer

Contact pressure measurements in total knee replacements are often made using a discrete sensor such as the Tekscan K-Scan sensor. However, no method currently exists for predicting the magnitude of sensor discretization errors in contact force, peak pressure, average pressure, and contact area, making it difficult to evaluate the accuracy of such measurements. This study identifies a non-dimen...

Journal: :The journal of knee surgery 2009
Matthew Provencher Neil S Ghodadra Nikhil N Verma Brian J Cole Stephanie Zaire Elizabeth Shewman Bernard R Bach

Patellofemoral kinematics after a limited resurfacing of the trochlea was investigated. Patellofemoral contact pressure, area, and force were measured for intact state; after creation of a 20-mm full-thickness trochlear defect; and after trochlear resurfacing implant (Arthrosurface) in serial flexion positions (45 degrees, 60 degrees, 75 degrees). In the defect state, edge loading and peak cont...

Vapor film formation and growth due to contact of a hot body and other liquids arise in some industrial applications including nuclear fuel rods, foundry and production of paper. The possibility of a steam explosion remains in most of these cases which could result in injuries and financial damage. Due to the importance of such phenomenon, this study deals with vapor layer forming, growth, and ...

2015
Simon Lee Thomas H. Wuerz Elizabeth Shewman Francis McCormick Michael Jonathan Salata Marc J. Philippon Shane Jay Nho

BACKGROUND Labral reconstruction using iliotibial band (ITB) autografts and semitendinosus (Semi-T) allografts has recently been described in cases of labral deficiency. PURPOSE/HYPOTHESIS To characterize the joint biomechanics with a labrum-intact, labrum-deficient, and labrum-reconstructed acetabulum in a hip cadaveric model. The hypothesis was that labral resection would decrease contact a...

2005
Carlos H. Hidrovo Fu-Min Wang Julie E. Steinbrenner Eon Soo Lee Sébastien Vigneron Ching-Hsiang Cheng John K. Eaton Kenneth E. Goodson

In this paper we present a first order study of liquid water detachment and entrainment into air flows in hydrophobic microchannels. A silicon based microfabricated test structure was used for this purpose. It consists of a 500 μm wide by 45 μm deep U-shaped channel 23 mm in length through which air is flown. The structures are treated with a Molecular Vapor Deposition (MVD) process that render...

Journal: :Journal of biomechanical engineering 2011
Nicolas V Jaumard Joel A Bauman Christine L Weisshaar Benjamin B Guarino William C Welch Beth A Winkelstein

The facet joint contributes to the normal biomechanical function of the spine by transmitting loads and limiting motions via articular contact. However, little is known about the contact pressure response for this joint. Such information can provide a quantitative measure of the facet joint's local environment. The objective of this study was to measure facet pressure during physiologic bending...

2001
Alain Borghijs

It is sometimes argued that resistance to nominal wage cuts would justify a moderate amount of inflation in order to “grease the wheels of the labour market”. While empirical studies tend to find that nominal wages are not downwardly rigid in Anglo-Saxon economies, a number of studies suggest that downward nominal wage rigidity is more widespread among continental European countries. This paper...

Journal: :نشریه دانشکده فنی 0
محمدعلی اخوان بهابادی دانشگاه تهران وحید حجازی دانشگاه تهران

in this research, heat transfer enhancement and simultaneous effect of that on pressure drop inside condensers with twisted tape inserts are investigated. a refrigeration system is designed for attaining to maximum level of heat transfer with minimum pressure drop. the test condenser is a double pipe heat transformer with inner and outer diameter of 10.7mm and 12.7mm for internal pipe, respecti...

2010
Shing-Hong Liu Chu-Chang Tyan

BACKGROUND Arterial pressure waveforms contain important diagnostic and physiological information since their contour depends on a healthy cardiovascular system 1. A sensor was placed at the measured artery and some contact pressure was used to measure the pressure waveform. However, where is the location of the sensor just about enough to detect a complete pressure waveform for the diagnosis? ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید