نتایج جستجو برای: cascade condenser
تعداد نتایج: 46670 فیلتر نتایج به سال:
The conventional design of air-conditioning plants using large-tonnage chillers calls for a condenser-water flow rate of 3 gallons-perminute-per-ton-of-refrigeration (GPM/TR). For years, this standard has been thought to offer a good balance between first cost and energy cost. Recently, this conventional design has been challenged by proponents of a 2 GPM/TR design. These proponents suggest tha...
1. The characteristics of the threshold excitation behavior of the squid giant axon were investigated with condenser discharges, exponentially blunted D. c. shocks, sinusoidal currents, and brief condenser-discharge test shocks superimposed at either electrode at controlled brief intervals following the closing of a constant current. 2. Data obtained by the use of condenser discharges and expon...
............................................................. 3 1.0: Project Importance: The Need for Alternative Fuels ................................................ 3 1.1 Background .............................................. 3 1.2: The Technological Challenge ...................... 4 2.0 Project Overview .......................................... 5 3.0 Experimentation: The difficulties...
This paper presents the exergy analysis of a desalination unit using humidification-dehumidification process. Here, this unit is considered as a thermal system with three main components, which are the heating unit by using a solar collector, the evaporator or the humidifier, and the condenser or the dehumidifier. In these components the exergy is a measure of the quality or grade of energy and...
Conventional control techniques are not able to accomplish the stable cooling in vapor compression air conditioning system. This paper describes the fuzzy models of refrigerating compressor, expansion valve, evaporator and condenser as basic elements of vapor compression air conditioning system. Compressor speed, delivery pressure, refrigerant flow rate, valve opening area, pressure difference ...
Preliminary note This paper presents the exergy destruction of an evaporator or a condenser or evaporator and condenser. The exergy destruction can be analytically calculated by using the same non-dimensional variables which have been used by its energy analysis. The one additional variable is the ratio of absolute input temperatures of both streams. This means that the given model enables the ...
In the case of multi-component condensation the ‘condensing vapour contains a mixture of components having different boiling points, which condense over a wide temperature range, either in presence of or absence of non-condensing material. In this work, a design algorithm for the condensation of a multi-component vapour mixture in shell side of a shell and tube vertical condenser has been devel...
Introduction The optical components of a microscope are its two imaging lenses (eyepiece and objective) and a condenser lens. The eyepiece and objective are responsible for magnifying the image of the specimen and projecting it onto the viewer’s retina or onto the film plane in a camera. The job of the condenser lens is to focus a cone of incident light onto the specimen. To provide the inciden...
We give new constructions of randomness extractors and lossless condensers that are optimal to within constant factors in both the seed length and the output length. For extractors, thismatches the parameters of the current best known construction [LRV03]; for lossless condensers,the previous best constructions achieved optimality to within a constant factor in one parameteronly at ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید