نتایج جستجو برای: ژنراتور dfig

تعداد نتایج: 2103  

2015
Youness Boukhris Aboubakr EL Makrini Hassane EL Markhi

This paper studies a control strategy to improve low voltage ride through (LVRT) capability of doubly fed induction generator (DFIG)-based wind turbine (WT). This solution is based on the DFIG with Crowbar circuit control and the installation of STATCOM which is connected at the point of common coupling (PCC). The simulation model of WTs with STATCOM is built using the environment MATLAB/Simuli...

2002
S. Müller M. Deicke Rik W. De Doncker

Wind turbines are being built at power levels above 1.5 MW. Higher power levels are being anticipated for off-shore applications. To limit mechanical stresses and power surges in these high power systems speed control is necessary. The doubly-fed induction generator (DFIG) system is investigated as a viable alternative to adjust speed over a wide range while keeping cost of the power converters...

2012
Xueguang Zhang Weiming Pan Yicheng Liu Dianguo Xu

This paper presents an improved grid voltage control strategy for wind farms with doubly-fed induction generators (DFIGs) connected to distribution networks based on an analysis of the operation limits of DFIG systems. A modified reactive power limit calculation method in different operation states is proposed and a reactive power control strategy during grid voltage dips/rises is further discu...

حسینی, سید مصطفی, پورفر, ایمان,

چکیده: بهره برداری از نیروگاه بادی به دلیل ماهیت متغیر باد و شبکه دارای مشکلاتی میباشد. به دلیل عدد ثبات در سرعت وزش باد توان خروجی نیروگاه بادی متغیر می باشد. این عد قطعیت موجب کاهش کنترل پذیری نیروگاههای بادی میگردد. مشکل دیگر، جزیره ای شدن نیروگاه از شبکه سراسری بر اثر خطا میباشد. در این شرایط عد تناسب بین توان تولیدی و توان مورد نیاز می باشد، افدزایش DFIGi بار در بخش جدا شده سیستم، موجب دور...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه اصفهان - پژوهشکده فنی و مهندسی 1391

مهمترین نیاز های حفاظتی برای ریزشبکه های متصل به شبکه تشخیص شرایط جزیره و حفاظت برای مقابله با شرایط جزیره می باشد. در این پایان نامه یک روش جدید برای تشخیص شرایط جزیره برای یک ریزشبکه استاندارد مجهز به منابع تولیدی مختلف شامل توربین بادی با ژنراتور القایی از دو سوء تغذیه (dfig)، chp و فتوولتائیک ارایه شده است. روش پیشنهادی تشخیص شرایط جزیره بر مبنای تزریق جریان اغتشاش به سیستم از طریق محور q ی...

2013
Akshay kumar

This paper presents the complete modeling and real-time simulation of wind turbine driven doubly-fed induction generator (DFIG) which feeds ac power to the utility grid. For that, two pulse width modulated voltage source converters are connected back to back between the rotor terminals and utility grid via common dc link. It is found that there are so many limitations in the conventional contro...

2013
Z. Boudjema

In this paper we present a nonlinear control using fuzzy sliding mode for wind energy conversion system based on a doubly-fed induction generator (DFIG) supplied by an AC-AC converter. In the first place, we carried out briefly a study of modeling on the whole system. In order to control the power flowing between the stator of the DFIG and the grid, a proposed control design uses fuzzy logic te...

2011
S. Wangsathitwong S. Sirisumrannukul S. Chatratana W. Deleroi

The unbalanced voltages cause negative effects on the doubly fed induction generator (DFIG) such as torque pulsation and increased stator current. Based on the symmetrical component theory, the torque pulsation is the consequence of the interaction of stator and rotor currents of different sequences. This paper presents a control technique to reduce the effect of unbalanced voltages on the DFIG...

2013
Alireza Zohoori Ahad Kazemi Rouhollah Shafaie

Grid disturbances, especially grid faults, have very unfavorable effect on the performance of wind turbine based Doubly Fed Induction Generator (DFIG). In this study active and reactive powers control of DFIG with STATCOM has been carried out to improve Fault Ride Through (FRT) capability of a wind turbine. In order to excel improvement of the DFIG behavior under grid fault disturbances, an opt...

2012
Ahmed G. Abo-Khalil

This paper presents a new synchronization algorithm for grid connection of a doubly fed induction generator (DFIG) in a variable speed wind generation system. Stator flux-oriented vector control for backto-back PWM converters in the DFIG rotor circuit is used for synchronization process. By controlling the rotor d-axis current, the magnitude of the stator EMF is adjusted to be equal to the grid...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید