نتایج جستجو برای: x ray detector
تعداد نتایج: 713717 فیلتر نتایج به سال:
Conventional explosive detection systems (EDS) based on X-ray technologies are using dual-energy radiography; they provide only a crude material characterization. Recently emerged semiconductors based X-ray detectors offer new capabilities in energy discrimination. This study is aiming at evaluating their interest for EDS. LETI-LDET laboratory has developed several pixellated CdTe/CZT detectors...
Single-crystal diffuse X-ray scattering was used to characterize radiation-induced defects in individual grains of a polycrystalline proton-irradiated Fe foil. The grains were probed with an intense 1 microm X-ray beam to demonstrate that both polycrystalline and micrometer-scale samples can be studied with single-crystal-like signal-to-noise. Scattering was measured with an X-ray-sensitive are...
In this paper we report on the design, fabrication, assembly and testing of an x-ray detector based on a bulk micromachined photodiode (BMMPD) with a cavity filled with a scintillating crystal. The x-ray photons that reach the detector are first converted to visible light by the scintillating crystal. The visible light is then detected by the BMMPD, producing an electric current with a value pr...
This paper presents development of an X-ray pixel detector with a multi-port charge-coupled device (MPCCD) for X-ray Free-Electron laser experiments. The fabrication process of the CCD was selected based on the X-ray radiation hardness against the estimated annual dose of 1.6 × 10(14) photon/mm(2). The sensor device was optimized by maximizing the full well capacity as high as 5 Me- within 50 μ...
Stereo x-ray radiography attracts increasing attention in major clinical applications. The purpose of this paper is to analyze the 3D localization error for breast biopsy procedures and provide guidelines for improving its accuracy. Our prototype is a CCD based digital stereo x-ray imaging system. The mathematical model consists of two x-ray sources and one stationary detector plane. A closed f...
This paper presents a portable total reflection X-ray fluorescence system composed of a 15 W X-ray tube, with a gold anode, a waveguide constituted by two Perspex(®) parallel plates, a Si PIN detector and a quartz optical flat. The critical angle of the total reflection system was experimentally determined by measuring a zinc solution (100 mg/L). The accuracy of the system was checked using SRM...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید