نتایج جستجو برای: tomography magnetic

تعداد نتایج: 502849  

Journal: :Revista espanola de enfermedades digestivas : organo oficial de la Sociedad Espanola de Patologia Digestiva 2012
Modesto Varas Joan Gornals José Luis Prieto Julio Iglesias-García

A: angiography; US: ultrasonography; EUS: endoscopic ultrasonography; IUS: intraoperative ultrasonography; EUS-FNA: endoscopic ultrasonography-guided fine-needle aspiration; MRI: magnetic resonance imaging; SRS: octreoscan; CT: computerized tomography; MDCT: multidetector computerized tomography; PET: positron emission tomography; PET-CT: PET with computerized tomography; ICC: immunocytochemist...

Journal: :Brazilian journal of anesthesiology 2016
Namik Ozcan Giray Ozcam Pinar Kosar Ayse Ozcan Hulya Basar Cetin Kaymak

BACKGROUND AND OBJECTIVES Carbon monoxide is a toxic gas for humans and is still a silent killer in both developed and developing countries. The aim of this case series was to evaluate early radiological images as a predictor of subsequent neuropsychological sequelae, following carbon monoxide poisoning. CASE 1 After carbon monoxide exposure, early computed tomography scans and magnetic reson...

Journal: :Journal of Cardiothoracic Surgery 2009
Engin Usta Christof Burgstahler Hermann Aebert Stephen Schroeder Uwe Helber Andreas F Kopp Gerhard Ziemer

BACKGROUND Cardiac allograft rejection and vasculopathy are the main factors limiting long-term survival after heart transplantation.In this pilot study we investigated whether non-invasive methods are beneficial to detect cardiac allograft rejection (Grade 03 R) and cardiac allograft vasculopathy. Thus we compared multi-slice computed tomography and magnetic resonance imaging with invasive met...

2005
HE F. Euchner K. Reinsch S. Jordan K. Beuermann B. T. Gänsicke

We report time-resolved optical flux and circular polarization spectroscopy of the magnetic DA white dwarf HE 1045−0908 obtained with FORS1 at the ESO VLT. Considering published results, we estimate a likely rotational period of Prot 2.7 h, but cannot exclude values as high as about 9 h. Our detailed Zeeman tomographic analysis reveals a field structure which is dominated by a quadrupole and co...

Journal: :Science 1982
G L Brownell T F Budinger P C Lauterbur P L McGeer

Noninvasive imaging methods for medical diagnosis and biological investigations, have evolved from qualitative radiological techniques to quantitative methods of measuring biochemical and physiological processes in human body. In particular, new developments in emission tomography, nuclear magnetic resonance imaging, and in vivo spectroscopy offer new horizons for medical research and clinical ...

2012
Joseph Stancanello

The introduction of tomographic imaging revolutionized the way we look at medical images. Compared to X-ray projective image, Computer Tomography (CT) offers the possibility of analyzing anatomical structures on a three-dimensional, slice-to-slice approach. On the other hand, limitations of CT consist of poor soft tissue contrast and ionizing radiation [1], while the advantages are distortion-f...

2004
Amy L. Oldenburg Jillian R. Gunther Farah Jean-Jacques Toublan Daniel L. Marks Kenneth S. Suslick Stephen A. Boppart

The magneto-mechanical effect is exploited as a means of producing background-free contrast in optical coherence tomography (OCT). Contrast agents consisting of iron-oxide particles and protein microspheres encapsulating colloidal iron-oxide have a sufficiently high magnetic susceptibility to be detected by modulation of a magnetic field gradient using a small solenoid coil. The externally-appl...

Journal: :iranian journal of nuclear medicine 2009
maria m d'souza rajnish sharma madhavi tripathi adhinav jaimini dinesh singh

we report an unusual case of a young male with cerebellar hemangioblastoma treated previously for medullary carcinoma of thyroid, whose pet/ct scans revealed a constellation of findings that suggested the rare von hippel lindau syndrome. the diagnosis was clinched by confirming the findings on whole body contrast enhanced computed tomography (cect) and contrast enhanced magnetic resonance imagi...

Journal: :Physiological measurement 2005
Levent Ozparlak Y Ziya Ider

Magnetic resonance-electrical impedance tomography (MR-EIT) is a conductivity imaging method based on injecting currents into the object. In this study, a new MR-EIT method, whereby currents are induced inside the object by using external coils, is proposed. This new method is called induced current magnetic resonance-electrical impedance tomography. In induced current MR-EIT surface electrodes...

2009
Serhat Avcu Özkan Ünal Halil Arslan

Herein, we report a 66 year old woman who was diagnosed to have intrabiliary rupture of liver hydatid cyst with demonstrative computed tomography, magnetic resonance imaging, and magnetic resonance cholangiopancreatography findings, with a review of the literature.

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید