نتایج جستجو برای: tissue equivalent phantom
تعداد نتایج: 1059439 فیلتر نتایج به سال:
background: radiotherapy plays an important role in the management of most malignant and many benign primary central nervous system (cns) tumors. radiotherapy affects both tumor cells and uninvolved normal cells; so, it is important to estimate absorbed dose to organs at risk in this kind of treatment. the aim of this study was to determine the absorbed dose to chiasma, lens, optic nerve, retin...
In the paper the research of flat textile products for use as electrodes was presented. Material’s resistance measurements were carried out to determine the suitability of the textiles. Based on the received results of studies different types of textile electrodes were designed. Textile electrodes tests were carried out on human phantoms. The electro-conductive properties of human forearm phant...
The purpose of this study was to validate the use of the circular harmonic transform (CHT) algorithm for quantitative single-photon emission computed tomography (SPECT) with isotopes technetium-99m (99mTc) and indium-111 (111In) under clinically relevant conditions. Phantom studies were the principal tools used. Volumes of fillable organs within a tissue-equivalent anthropomorphic phantom were ...
A popular alternative of preparing multilayer or microfluidic chip based phantoms could have helped to simulate the subsurface vascular network, but brought inevitable problems. In this work, we describe the preparation method of a single layer skin equivalent tissue phantom containing interior vessel channels, which mimick the superficial microvascular structure. The fabrication method does no...
Equivalent dose from neutrons produced during proton radiotherapy increases the predicted risk of radiogenic late effects. However, out-of-field neutron dose is not taken into account by commercial proton radiotherapy treatment planning systems. The purpose of this study was to demonstrate the feasibility of implementing an analytical model to calculate leakage neutron equivalent dose in a trea...
PURPOSE The authors present a calibration method for a prototype proton computed tomography (pCT) scanner. The accuracy of these measurements depends upon careful calibration of the energy detector used to measure the residual energy of the protons that passed through the object. METHODS A prototype pCT scanner with a cesium iodide (CsI(Tl)) crystal calorimeter was calibrated by measuring the...
The determination of the dosimetry parameters of brachytherapy in the treatment of cancerous tumors as per the TG-43U1 protocol provided by the American Association of Physicists in Medicine should be done in the surrounding water source before clinical application. To achieve a good treatment result, various factors such as body tissues with different densities can have a decisive role so that...
INTRODUCTION Wide agreement has been reached among the main Bodies and Organizations involved in standardization of radiation protection to define as operational quantity for individual monitoring of external exposure, the personal dose equivalent, Hp(d) (1,2,3). However, as Hp(d) is defined in the human body, it is not a measurable quantity. In practice, it has to be estimated from the indicat...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید