نتایج جستجو برای: ti anomaly

تعداد نتایج: 74396  

Journal: :Journal of biomedical materials research. Part A 2007
A G Secchi V Grigoriou I M Shapiro E A Cavalcanti-Adam R J Composto P Ducheyne C S Adams

A major cause of implant failure in skeletal tissues is failure of osseointegration, often due to lack of adhesion of cells to the titanium (Ti) alloy interface. Since arginine-glycine-aspartic acid (RGD)-containing peptides have been shown to regulate osteoblast adhesion, we tested the hypothesis that, bound to a Ti surface, these peptides would promote osteoblasts differentiation, while at th...

2012
Yoshimitsu Okazaki

The fatigue strength, effects of a notch on the fatigue strength, and fatigue crack growth rate of Ti-15Zr-4Nb-4Ta alloy were compared with those of other implantable metals. Zr, Nb, and Ta are important alloying elements for Ti alloys for attaining superior long-term corrosion resistance and biocompatibility. The highly biocompatible Ti-15Zr-4Nb-4Ta alloy exhibited an excellent balance between...

Journal: :Journal of the mechanical behavior of biomedical materials 2017
Hyelim Choi Serge Shil'ko Jenő Gubicza Heeman Choe

Ti and Ti‒5wt% W alloy foams were produced by freeze-casting process and their mechanical behaviors were compared. The Ti‒5W alloy foam showed a typical acicular Widmanstätten α/β structure with most of the W dissolved in the β phase. An electron-probe microanalysis revealed that approximately 2wt% W was uniformly dissolved in the Ti matrix of Ti‒5W alloy foam with few partially dissolved W par...

Journal: :international journal of reproductive biomedicine 0
shohreh irani firoozeh ahmadi maryam javam ahmad vosoughtaghi dizaj fatemeh niknejad

background: several studies have assessed the correlation of fetal choroid plexus cyst (cpc) and the risk of congenital anomalies, but few ones have discussed isolated cpc (with no other abnormal sonographic finding). objective: the aim of this study was to determine the outcome of isolated fetal choroid plexus cyst and to specify its clinical significance. materials and methods: this cross sec...

2010
Yang Liu Michael J. Spicuzza Paul R. Craddock John W. Valley Nicolas Dauphas Lawrence A. Taylor

Oxygen and iron isotope analyses of low-Ti and high-Timare basalts are presented to constrain their petrogenesis and to assess stable isotope variations within lunar mantle sources. An internally-consistent dataset of oxygen isotope compositions of mare basalts encompasses five types of low-Ti basalts from the Apollo 12 and 15 missions and eight types of high-Ti basalts from the Apollo 11 and 1...

Journal: :فصلنامه علمی پژوهشی مهندسی مکانیک جامدات واحد خمینی شهر 0
amir qysryan ma, identification and selection of materials engineering, university of kashan, kashan, iran. mahmood abasi assistant professor, faculty of engineering, department of materials and metallurgical engineering, university of kashan, kashan, iran

ti-6al-4v titanium alloy has great application in medicine and military industries due to its capabilities, namely high strength to weight ratio and corrosion resistance. in the current research, the effect of aging treatment on microstructure and wear behavior of ti-6al-4v titanium alloy was investigated. pin on disk wear test was applied to assess the wear behavior. specimens were first solut...

Journal: :international journal of iron & steel society of iran 2006
m. toroghinejad g. dini

a low carbon al-killed ti-added steel was produced in mobarakeh steel complex in iran. mechanical properties and microstructural characterizations of steel in the as-cast, hot-rolled, cold-rolled and annealed conditions are presented. dilatometery tests were carried out to measure the finishing and annealing temperatures of steel. it was found that the addition of small amounts of ti increased ...

2009
Per Eklund Hans Högberg Lars Hultman O. Wilhelmsson P. Eklund H. Högberg L. Hultman

2014
Wan-Geun La Min Jin Saibom Park Hee-Hun Yoon Gun-Jae Jeong Suk Ho Bhang Hoyoung Park Kookheon Char Byung-Soo Kim

In this study, we demonstrate that graphene oxide (GO) can be used for the delivery of bone morphogenetic protein-2 (BMP-2) and substance P (SP), and that this delivery promotes bone formation on titanium (Ti) implants that are coated with GO. GO coating on Ti substrate enabled a sustained release of BMP-2. BMP-2 delivery using GO-coated Ti exhibited a higher alkaline phosphatase activity in bo...

2015
Tiangui You Xin Ou Gang Niu Florian Bärwolf Guodong Li Nan Du Danilo Bürger Ilona Skorupa Qi Jia Wenjie Yu Xi Wang Oliver G. Schmidt Heidemarie Schmidt

BiFeO3 based MIM structures with Ti-implanted Pt bottom electrodes and Au top electrodes have been fabricated on Sapphire substrates. The resulting metal-insulator-metal (MIM) structures show bipolar resistive switching without an electroforming process. It is evidenced that during the BiFeO3 thin film growth Ti diffuses into the BiFeO3 layer. The diffused Ti effectively traps and releases oxyg...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید