نتایج جستجو برای: steel beam

تعداد نتایج: 191338  

2002
J. Corbett R. Akre P. Bellomo R. Boyce L. Cadapan R. Cassel B. Choi R. Fuller A. Garren P. Rodriguez

SPEAR 3 is an upgrade of the 18-cell SPEAR 2 storage ring to 3GeV beam energy, 18nm-radian emittance and up to 500mA circulating current. The existing arrangement of photon beam lines remains largely unchanged, but opportunities arise for additional ID and dipole radiation exit ports. For optimum beam stability, the entire tunnel floor will be excavated and replaced with reinforced concrete. Th...

2013
Khan Ahmed

It is observed that, reinforced concrete beams failed due to flexure but in case of deep beam failure occur due to shear. Deep beams may be defined as the beam where shear span to depth ratio less than 2. A number of researchers already proposed various approach to predict the ultimate strength of deep beams. In this study a newer approach is developed to calculate the ultimate shear strength o...

2012
S. S. Patil A. N. Shaikh B. R. Niranjan

ABSTRACT: Several reinforced concrete deep beams with different L/D ratios (1.5, 1.6, 1.71) were cast and tested in order to investigate the strain distribution pattern at mid-section of the beam. This paper describes analysis of deep beams subjected to two point loading with three different L/D ratios (1.5, 1.6, 1.71) using Non-linear Finite element method (ANSYS 9.0 software). In ANSYS 9.0 so...

2016
Anh Tuan Tran

Hollow sections have been widely used for steel structures. Applications of High Strength Steel (HSS) on cold-formed hollow sections lead to thinner and lighter structures. This paper presents numerical investigations on the lateral-torsional buckling resistance of the cold-formed high strength steel rectangular hollow beam. Results from finite element analysis using Abaqus software are compare...

Journal: :Journal of Structural and Construction Engineering (Transactions of AIJ) 2019

A. Nabati, S. Gholizadeh,

The present work is aimed at assessing the impact of strong column-weak beam (SCWB) criterion on seismic performance of optimally designed steel moment frames. To this end, different SCWB ratios are considered for steel special moment resisting frame (SMRF) structures and performance-based design optimization process is implemented with the aid of an efficient metaheuristic. The seismic collaps...

Journal: :E3S web of conferences 2021

This paper has carried out the quasi-static tests of five specimens FRP-UHPC column-steel beam joints with core columns, and extensive parameter analysis by numerical simulation. The results show that Concrete-filled square steel tube column -Steel Beam Joints have strong bearing capacity. It excellent deformability, stiffness energy dissipation capacity, works well under condition high axial c...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه صنعتی امیرکبیر(پلی تکنیک تهران) - دانشکده مهندسی 1388

در سالیان اخیر حرکت جدیدی در طراحی سازه ها، به سمت استفاده از معیار طراحی حدی آغاز شده است. در این معیار عملکرد سازه در حالت های مختلف حدی متناسب با آن سازه مورد بررسی قرار می-گیرد. حالت حد نهایی یا استحکام نهایی از جمله حالت های حدی مهمی است که برای سازه های فولادی در نظر گرفته می شود. در کشتی به عنوان یک سازه فولادی، اولین گام در محاسبات سازه ای، محاسبه استحکام شاه تیر آن می باشد که خود تاب...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه یاسوج - دانشکده فنی 1389

روش مقاومت مستقیم (dsm)، اولین¬بار، به صورت یک دسته معادله¬، برای اعضای فولادی سرد¬ساخت در مشخصات آئین¬نامه aisi، ارائه شد که بعد از انجام تحقیقات گسترده به عنوان روشی طراحی برای اعضای فولادی سرد¬ساخت توسعه یافته است که از آن می¬توان بعنوان یک روش طراحی برای اعضای فولادی سرد¬ساخت فشاری، خمشی، برشی، تیر¬ستون¬ها و سوراخ¬دار استفاده کرد. در سالهای اخیر، سعی شده است که از dsm برای طراحی اعضای فولاد...

2013
N. H. Hamid N. D. Hadi K. D. Ghani

─This paper presents the retrofitting of beam-column joint using CFRP (Carbon Fiber Reinforced Polymer) and steel plate. This specimen was tested until failure up to 1.0% drift. This joint suffered severe damages and diagonal cracks at upper crack at upper column before retrofitted. CFRP were wrapped at corbel, bottom and top of the column. Steel plates with bonding were attached to the two bea...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید