نتایج جستجو برای: spect ct

تعداد نتایج: 142504  

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2013
Camilla Schalin-Jäntti Eeva Ryhänen Ilkka Heiskanen Marko Seppänen Johanna Arola Jukka Schildt Mika Väisänen Lassi Nelimarkka Irina Lisinen Ville Aalto Pirjo Nuutila Matti J Välimäki

UNLABELLED All patients with primary hyperparathyroidism should undergo localization studies before reoperation, but it is not known which method is most accurate. The purpose of this prospective study was to compare the performance of planar scintigraphy with (123)I/(99m)Tc-sestamibi, (99m)Tc-sestamibi SPECT (SPECT/CT), (11)C-methionine PET/CT, and selective venous sampling (SVS) in persistent...

Journal: :Nuclear medicine review. Central & Eastern Europe 2013
Otakar Kraft Martin Havel

BACKGROUND Aim ot the study was to assess the role of planar lymphoscintigraphy and fusion imaging of SPECT/CT in sentinel lymph node (SLN) detection in patients with various types of tumours and to estimate some factors influencing detection success - age and body mass index. MATERIAL AND METHODS Planar scintigraphy and hybrid modality SPECT/CT were performed in 550 consecutive patients (mea...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2009
Angela Spanu Maria E Solinas Francesca Chessa Daniela Sanna Susanna Nuvoli Giuseppe Madeddu

UNLABELLED Planar 131I scintigraphy is routinely used to detect radioiodine-avid metastases of differentiated thyroid carcinoma (DTC). However, the modality has limitations, such as low sensitivity and lack of anatomic landmarks. We investigated whether SPECT with integrated low-dose CT may have additional value over planar imaging in detecting residue and metastases in DTC patients. METHODS ...

2014
Yung Hsiang Kao Butch M Magsombol Ying Toh Kiang Hiong Tay Pierce KH Chow Anthony SW Goh David CE Ng

BACKGROUND For yttrium-90 ((90)Y) radioembolization, the common practice of assuming a standard 1,000-g lung mass for predictive dosimetry is fundamentally incongruent with the modern philosophy of personalized medicine. We recently developed a technique of personalized predictive lung dosimetry using technetium-99m ((99m)Tc) macroaggregated albumin (MAA) single photon emission computed tomogra...

2010
Tzyy-Ling Chuang Yuh-Feng Wang Chun-Liang Lai

We present the characteristics of a ventilation-perfusion scan correlating to both planar and single photon emission computed tomography and computed tomography (SPECT/CT) images of the lungs in a patient with SwyerJames (MacLeod) syndrome. A Tc-99m MAA lung perfusion scan was recorded with multiple projections and SPECT/CT. In the ventilation scan, initially dynamic acquisition of aerosol Tc-9...

Journal: :Cancer research 1995
S Katyal E L Kramer M E Noz D McCauley A Chachoua A Steinfeld

In non-small cell lung cancer (NSCLC), accurate staging is critical in deciding between potentially curative surgery and palliative treatment. Image registration, or fusion, combines the unique functional information provided by SPECT imaging with the excellent anatomic detail offered by computed tomography (CT) or magnetic resonance imaging to better characterize the information provided by ea...

Journal: :Journal of B.U.ON. : official journal of the Balkan Union of Oncology 2017
Guoliang Xia Chuanguo An Zonghua Ming Hong Guo Lihong Liu Yufeng Li

PURPOSE To compare the diagnostic value of 99Tcm-MIBI- SPECT and 18F-FDG-PET/CT in differentiating benign from malignant solitary pulmonary nodules (SPNs). METHODS 170 SPNs were involved in this study (78 with 99Tcm-MIBI-SPECT and 92 with 18F-FDG-PET/CT). Definite diagnosis of SPNs was determined by biopsy. The diagnostic efficiency of 99Tcm-MIBI-SPECT and 18F-FDGPET/ CT in differentiating be...

Journal: :Nuclear medicine communications 2012
Babak Shafiei Samaneh Hoseinzadeh Fereidoun Fotouhi Hadi Malek Fereidoun Azizi Adel Jahed Farzad Hadaegh Mohammadtaghi Salehian Hossein Parsa Hamid Javadi Majid Assadi

BACKGROUND Investigations using a hybrid single photon emission computed tomography/computed tomography (SPECT-CT) scanning technique have been carried out in limited studies and have shown mixed results. However, the assessment of this technique for the detection of parathyroid adenoma in patients with a nodular goiter was performed in only one study with a small sample size. The aim of this p...

Journal: :American journal of nuclear medicine and molecular imaging 2012
Peeyush Bhargava Guocheng He Amin Samarghandi Ebrahim S Delpassand

Integrated SPECT/CT scanners are gaining popularity as hybrid molecular imaging devices which can acquire SPECT and CT in a single exam. CT can be a low dose non-contrast enhanced scan for attenuation correction and anatomical localization, or a contrast enhanced diagnostic quality scan for additional anatomical characterization. We present a pictorial review highlighting the usefulness of this...

2016
Haishan Zhang Shi Gao Bin Chen Guanghui Cheng

The aim of the present study was to compare technetium-99m-(polyethylene glycol-4)3-(Arg-Gly-Asp)2 (99mTc-3P4-RGD2) single-photon emission computed tomography (SPECT) and computed tomography (CT) in the noninvasive differentiation of solitary pulmonary nodules (SPNs). The present study prospectively investigated a consecutive series of 24 patients with SPN, who were newly diagnosed using radiog...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید