نتایج جستجو برای: small field dosimetry

تعداد نتایج: 1519041  

Introduction For dose measurement in Megavoltage (MV) photon beams with ion chambers, the effect of volume occupied by the air cavity is not negligible. Therefore, the result of measurement should be corrected with a displacement perturbation correction factor (Pdis) or using an effective point of measurement (EPOM). The aim of this study is to calculate the EPOM for cylindrical ion chamber and...

2013
M. Benabdesselam F. Mady

This study analyses the thermally stimulated luminescence or thermoluminescence (TL) glow curve between 300 and 773 K of germanium-doped silica optical fibre. A main glow peak at 530 K with a characteristic spectral emission centred at 400 nm is found. Both features are particularly suitable for dosimetry. Thus, an investigation by the TL technique of some first clinically relevant features of ...

Journal: :Physics in medicine and biology 2000
T Samaras P Regli N Kuster

Reliable information on the heat distribution inside biological tissues is essential for the planning and optimization of experiments which aim to study the effects of non-ionizing radiation (NIR). In electrodynamics, the finite-difference time-domain (FDTD) technique has become the dominant technique for radiofrequency dosimetry. In order to obtain the electromagnetic field and heat distributi...

2008
Antonio Delgado

Some of the more relevant recent achievements and developments in the field of external radiation dosimetry are reviewed in this presentation. Among them, topics related to personal dosimetry, as the relative role of active and passive methods and the features of some recently proposed new methods. Electronic personal dosemeters and Optically Stimulated Luminescence, OSL, have already accredite...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2007
George Sgouros

Dosimetry for targeted radionuclide therapy is a relatively young field. Although initial work can be traced back to the late 1940s (1), the MIRD Committee formalism that forms the foundation for most current approaches was published in the mid 1970s (2), and the drive for improved dosimetry to meet the requirements of targeted radionuclide therapy did not begin until the 1980s. During this per...

2017
Arpita Agarwal Nikhil Rastogi K. J. Maria Das S. A. Yoganathan D. Udayakumar Shaleen Kumar

PURPOSE With the advent of state-of-the-art treatment technologies, the use of small fields has increased, and dosimetry in small fields is highly challenging. In this study, the potential use of Varian electronic portal imaging device (EPID) for small field measurements was explored for 6 and 15 MV photon beams. MATERIALS AND METHODS The output factors and profiles were measured for a range ...

2014
Vibha Chaswal Michael Weldon Nilendu Gupta Arnab Chakravarti Yi Rong

We present commissioning and comprehensive evaluation for ArcCHECK as a QA equipment for volumetric-modulated arc therapy (VMAT), using the 6 MV photon beam with and without the flattening filter, and the SNC patient software (version 6.2). In addition to commissioning involving absolute dose calibration, array calibration, and PMMA density verification, ArcCHECK was evaluated for its response ...

Journal: :Physics in medicine and biology 2016
Pedro Andreo Hugo Palmans Maria Marteinsdóttir Hamza Benmakhlouf Åsa Carlsson-Tedgren

Monte Carlo (MC) calculated detector-specific output correction factors for small photon beam dosimetry are commonly used in clinical practice. The technique, with a geometry description based on manufacturer blueprints, offers certain advantages over experimentally determined values but is not free of weaknesses. Independent MC calculations of output correction factors for a PTW-60019 micro-di...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید