نتایج جستجو برای: signal to noise

تعداد نتایج: 10703107  

Journal: :نشریه دانشکده فنی 0
دکتر اردشیر گویری

phase sensitive detector described here has two principal applications: a- to produce a d.c out put proportional to- the amplitude of an incoming a,c signal and indicate, by the outut polarity, the phase of the signal with respect to an internal reference. b- to detect the presence of a signal of known phase and frequency which would otherwise be lost in «background noise» and to measure its am...

Faraz Kalantari, Hadi Noori Eskandari, Mohsen Hajizadeh Saffar Peter Knoll, Seyed Rasoul Zakavi Shabnam Oloomi

  Objective(s): In SPECT, the sinogram contains scatter and lack of attenuated counts that degrade the reconstructed image quality and quantity. Many techniques for attenuation and scatter correction have been proposed. An acceptable method of correction is to incorporate effects into an iterative statistical reconstruction. Here, we propose new Maximum Likelihood Expectation Maximiz...

Journal: :journal of biomedical physics and engineering 0
s. abbaspour a. fallah

background: the electrocardiogram artifact is a major contamination in the electromyogram signals when electromyogram signal is recorded from upper trunk muscles and because of that the contaminated electromyogram is not useful. objective: removing electrocardiogram contamination from electromyogram signals. methods: in this paper, the clean electromyogram signal, electrocardiogram artifact and...

Traditional noise removal methods like Non-Local Means create spurious boundaries inside regular zones. Visushrink removes too many coefficients and yields recovered images that are overly smoothed. In Bayesshrink method, sharp features are preserved. However, PSNR (Peak Signal-to-Noise Ratio) is considerably low. BLS-GSM generates some discontinuous information during the course of denoising a...

ژورنال: ژئوفیزیک ایران 2015
Ahmad MadanchiZare Hamid Dehghani Kiomars Mosazadeh Maysam Abedi

This paper describes the application of three straightforward image-based filtering methods to remove the geological noise effect which masks unexploded ordnances (UXOs) magnetic signals in geophysical surveys. Three image filters comprising of mean, median and Wiener are used to enhance the location of probable UXOs when they are embedded in a dominant background geological noise. The study ar...

Journal: :iranian journal of radiology 0
jian hui gu jiangsu province key laboratory of neuroregeneration, nantong university, nantong, jiangsu, china xue jun zhou department of radiology, affiliated hospital of nantong university, nantong, jiangsu, china dong sheng jin department of radiology, jiangsu province official hospital, nanjing, jiangsu, china wen quan ding department of hand surgery, ningbo no.6 hospital, ningbo university, ningbo, zhejiang, china; department of hand surgery, ningbo no.6 hospital, ningbo university, ningbo, zhejiang, china. tel: +86-18106606963 xin wang department of hand surgery, ningbo no.6 hospital, ningbo university, ningbo, zhejiang, china

conclusion vr reconstruction for both single-direction images and sushi using dti25 raw data provides excellent 3d displays of the peripheral nerves in the wrist region. sushi post-processing is a useful denoising tool because it automatically reduces the majority of isotropic object noise. results single-direction vr reconstruction clearly showed the nerves for both dti6 and dti25 but with obv...

2007
B. Demir

An adaptive modification to the two-bit transform-based low-complexity block motion estimation approach is proposed. Initially, video frames are converted into two-bit representations using the two-bit transform (2BT), and binary block-based motion estimation is performed using these two bit-planes. Modification to the original 2BT-based motion estimation scheme is introduced by conditional loc...

2009
Kuo-Liang Chung Wei-Jen Yang Ting-Chin Chang Hong-Yuan Mark Liao

Reversible data hiding can guarantee that the original image can be recovered from the marked image without any distortion. In this paper, an efficient multilevel reversible data hiding algorithm for video sequences is presented. Since the gray level distribution of the difference map is Laplacian, the peak point of the distribution thus leads into high data hiding capacity and good image quali...

2008
Matthieu Klein Abdelhakim Bendada Mariacristina Pilla Clemente Ibarra-Castanedo Xavier Maldague

In pulsed thermography the sample to test is briefly heated with a Dirac δ heat impulse and then observed through an infrared (IR) camera recording thermal images as the sample is cooling down. The difference of temperature on the IR images between the defective areas and the sound areas is referred to as a thermal contrast [1]. The Signal-to-Noise Ratio (SNR) of such a contrast is strongly aff...

2002
T. Merle

[6]. ABSTRACT: The influence of different useful recording parameters in Fourier transform infrared spectra, on the signal-to-noise ratio is considered. We particularly studied the evolution of the signal to noise ratio with the spectral resolution, the transmission of different samples, the intensity of the background and the number of scans. This will allow an optimal extraction of spectral i...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید