نتایج جستجو برای: semiconductor detectors

تعداد نتایج: 92478  

2001
Martin Hoheisel Lothar Bätz

Solid state X-ray detectors based on large-area amorphous semiconductors such as amorphous silicon or selenium have been developed. The requirements for various applications in medical diagnosis determine the boundary conditions for different detectors. Key parameters are image receptor size, spatial resolution, image frequency, signal-to-noise ratio, and long-term stability. Conventional thora...

2016
Bin Fang Mario Carpentieri Xiaojie Hao Hongwen Jiang Jordan A Katine Ilya N Krivorotov Berthold Ocker Juergen Langer Kang L Wang Baoshun Zhang Bruno Azzerboni Pedram Khalili Amiri Giovanni Finocchio Zhongming Zeng

Microwave detectors based on the spin-torque diode effect are among the key emerging spintronic devices. By utilizing the spin of electrons in addition to charge, they have the potential to overcome the theoretical performance limits of their semiconductor (Schottky) counterparts. However, so far, practical implementations of spin-diode microwave detectors have been limited by the necessity to ...

2017
Anatoly B. Rosenfeld

Modern radiation therapy is very conformal, resulting in a complexity of delivery that leads to many small radiation fields with steep dose gradients, increasing error probability. Quality assurance in delivery of such radiation fields is paramount and requires real time and high spatial resolution dosimetry. Semiconductor radiation detectors due to their small size, ability to operate in passi...

2003
K. Zuber Denys Wilkinson

Various double beta decay modes of Cd, Zn and Te isotopes are explored with the help of CdTe and CdZnTe semiconductor detectors. The data set is splitted in an energy range below 1MeV having a statistics of 134.5 g·d and one above 1MeV resulting in 532 g·d. No signals were observed in all channels under investigation. New improved limits for the neutrinoless double beta decay of Zn of T1/2 > 1....

Journal: :Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 2018

2006
C.A.N. Conde

The effect of the presence of a drift electric field on the response of gaseous and semiconductor radiation detectors to energetic X-rays (energies Eph from 20 to 200 keV) is investigated using the PENELOPE code to simulate the photo-absorption and the slow-down of the electrons produced in Si, Ge, and Xe gas at 1 atm. For typical drift fields, the energy Ed deposited in the detection media is ...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه رازی - دانشکده علوم 1387

boron nitride semiconducting zigzag swcnt, $b_{cb}$$n_{cn}$$c_{1-cb-cn}$, as a potential candidate for making nanoelectronic devices was examined. in contrast to the previous dft calculations, wherein just one boron and nitrogen doping configuration have been considered, here for the average over all possible configurations, density of states (dos) was calculated in terms of boron and nitrogen ...

M. Allahverdi M. Esfahani M. Taghizadeh Dabbagh P. Haddad

Introduction: During radiotherapy, high accuracy in the dose delivery is required because there is a strong  relationship between the absorbed dose, local tumor control and particularly the normal tissue damage. In  many institutions, in vivo dosimetry using diodes is performed to check the actual dose delivered. In general,  the uncertainty in the dose delivered should fall within  ± 5% of the...

Journal: :Mass spectrometry reviews 1999
M Frank S E Labov G Westmacott W H Benner

Energy-sensitive calorimetric detectors that operate at low temperatures ("cryogenic detectors") have recently been applied for the first time as ion detectors in time-of-flight mass spectrometry. Compared to conventional, ionization-based detectors, which rely on secondary electron formation or the charge created in a semiconductor, cryogenic detectors measure low-energy solid state excitation...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید