نتایج جستجو برای: pm10

تعداد نتایج: 4256  

Journal: :Journal of the Air & Waste Management Association 1996
Chuen JinnTsai Yu-Hsiang Cheng

This paper reports on the performance of the Kimoto 180 sampler and the Wedding ambient PM10 beta gauge sampler. Monodisperse ammonium fluorescein test particles were generated in the laboratory and used to determine the penetration curve of the Kimoto 180 cyclonic inlet. It was found that the actual DpaSOof the Kimoto 180 inlet, 3.5 (xm, is much lower than the designated standard value, 10 um....

2003
John D. Wanjura Calvin B. Parnell Bryan W. Shaw Ronald E. Lacey

The regulation of particulate matter (PM) emitted by agricultural sources (cotton gins, feed mills, concentrated animal feeding operations (CAFOs) is based upon downwind concentrations of particulate matter less than 10 and 2.5 micrometers (μm) (PM10 and PM2.5) aerodynamic equivalent diameter (AED). Both PM10 and PM2.5 samplers operate by pre-separating PM larger than the size of interest (10 a...

Journal: :Occupational and environmental medicine 1999
S A Bremner H R Anderson R W Atkinson A J McMichael D P Strachan J M Bland J S Bower

OBJECTIVES A previous study of the short term effects of air pollution in London from April 1987 to March 1992 found associations between all cause mortality and black smoke and ozone, but no clear evidence of specificity for cardiorespiratory deaths. London data from 1992 to 1994 were analysed to examine the consistency of results over time and to include particles with a mean aerodynamic diam...

2013
Duckshin Park Soon-Bark Kwon Youngmin Cho

A Zigbee-based ubiquitous sensor network (USN) has many industrial applications and provides flexible measuring environments. In particular, the USN system can replace existing measuring devices in harsh environments such as subway stations. To monitor the intensities of various pollutants and air qualities in subway tunnels, this study applied the USN technique. A novel wireless sensor module,...

Journal: :BMC Public Health 2007
Fay H Johnston Ross S Bailie Louis S Pilotto Ivan C Hanigan

BACKGROUND Increasing severe vegetation fires worldwide has been attributed to both global environmental change and land management practices. However there is little evidence concerning the population health effects of outdoor air pollution derived from biomass fires. Frequent seasonal bushfires near Darwin, Australia provide an opportunity to examine this issue. We examined the relationship b...

Journal: :Indoor air 2010
B Pekey Z B Bozkurt H Pekey G Doğan A Zararsiz N Efe G Tuncel

This study presents indoor/outdoor PM2.5 and PM10 concentrations measured during winter and summer in 15 homes in Kocaeli, which is one of the most industrialized areas in Turkey. Indoor and outdoor PM2.5 and PM10 mass concentrations and elemental composition were determined using an X-ray fluorescence spectrometer. Quantitative information was obtained on mass concentrations and other characte...

2017
Branislava Matic Uros Rakic Verica Jovanovic Snezana Dejanovic Nela Djonovic

INTRODUCTION Indoor air quality (IAQ) is rated as a serious public health issue. Knowing children are accounted as more vulnerable to environmental health hazards, data are needed on air quality in schools. METHODS A project was conducted from 2007 until 2009 (SEARCH, School Environment and Respiratory Health of Children), aiming to verify links between IAQ and children's respiratory health. ...

Journal: :The American journal of cardiology 2016
Muthiah Vaduganathan Giuseppe De Palma Alessandra Manerba Matteo Goldoni Marco Triggiani Pietro Apostoli Livio Dei Cas Savina Nodari

The association between exposure to air pollution and acute cardiovascular (CV) events is well documented; however, limited data are available evaluating the public health safety of various "doses" of particular matter (PM) below currently accepted safety thresholds. We explored the cross-sectional association between PM with aerodynamic diameter <10 μm (PM10) and daily CV hospitalizations in B...

Journal: :Journal of environmental quality 2006
B S Sharratt D Lauer

The USEPA has proposed to regulate PM(coarse) (particulate matter 2.5 to 10 microm in diameter). Exceedance of the proposed National Ambient Air Quality Standard (NAAQS) for PM(coarse) is expected within the Columbia Plateau of the Pacific Northwest United States based on the high frequency of dust storms and the large contribution of crustal material to fugitive dust in the region. The objecti...

2015
Akbar Gholampour Ramin Nabizadeh Mohammad Sadegh Hassanvand Hasan Taghipour Shahrokh Nazmara Amir Hossein Mahvi

Compared with common dust storms, saline dust storms transport high concentrations of fine-grain saline and alkaline material. The saline dust storm differs from common dust storm, especially considering the sources of the suspended particulate matter (PM), chemical composition, grain size, and circulation processes. Atmospheric particulate matters (TSP, PM10, PM2.5, and PM1) and their water-so...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید