نتایج جستجو برای: plastic track detectors

تعداد نتایج: 150117  

2011
Lin M. M. Myint Pornchai Supnithi Prinya Tantaswadi

In this paper, we studied the performance of the iterated Viterbi detection methods using the multi-track multi-head processing for a bit patterned media (BPM) channel with a two-dimensional interference consisting of inter-symbol interference (ISI) and inter-track interference (ITI). In each method, three Viterbi detectors are employed to process the three readback signals. In their trellises,...

ژورنال: سنجش و ایمنی پرتو 2020

The origins of radon gas are the amount of uranium decay in the soil that is released into space and through the interior gaps of  buildings. Radon can enter the respiratory system and cause radiation hazards. Recently research has identified Radon as the second leading cause of lung cancer after cigarette smoking. The indoor concentration of Radon progeny is mentioned as an important issue reg...

2001
Greg A. Voth Arthur La Porta Alice M. Crawford Eberhard Bodenschatz Jim Alexander

We describe a high speed imaging system that is used to track tracer particles in highly turbulent flows. The system uses silicon strip detectors designed for high energy physics experiments and is capable of reading two detectors at a frame rate of 70 kHz. Each detector contains 512 strips and measures a one-dimensional projection of the light striking it. The position measurements from this s...

2008
W. D. Hulsbergen

We present an expression for the covariance matrix of the set of state vectors describing a track fitted with a Kalman filter. We demonstrate that this expression facilitates the use of a Kalman filter track model in a minimum χ2 algorithm for the alignment of tracking detectors. We also show that it allows to incorporate vertex constraints in such a procedure without refitting the tracks.

Journal: :iranian journal of radiation research 0
k. kant department of physics, kl mehta dayanand college for women, faridabad, haryana, india-121 001 s.b. upadhyay department of physics, b.s.a. college, mathura ,u.p. – 281 001 s.k. chakarvarti department of applied physics, n.i.t. kurukshetra, haryana, india-136 119

abstract background: and soils with which it comes in contact. there is dual exposure from radon in water i.e. due toinhalation of the radon released from the water into the ambient air and through ingestion whenwater is used for drinking. as radon contaminated water adversely affects the health, it istherefore fundamental from health and hygiene point of view to measure radium concentrationand...

Journal: :Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 2020

1999
P. F. Bloser

We report on the design and laboratory testing of a prototype imaging CZT detector intended for balloon flight testing in April 2000. The detector tests several key techniques needed for the construction of large-area CZT arrays, as required for proposed hard X-ray astronomy missions. Two 10 mm × 10 mm × 5 mm CZT detectors, each with a 4 × 4 array of 1.9 mm pixels on a 2.5 mm pitch, will be mou...

2005
S. Balestra

We discuss the properties of cosmic ray nuclearites, from the point of view of their search with large nuclear track detector arrays exposed at different altitudes, in particular with the SLIM experiment at the Chacaltaya high altitude lab (5290 m a.s.l.). We present calculations concerning their propagation in the Earth atmosphere and discuss their possible detection with CR39 and Makrofol nuc...

2007
Martin Weber

CMS silicon Tracker alignment consists of three key components: Survey during tracker construction, measurements with the Laser Alignment System during operation and track based alignment. Methods and results are explained in detail, with a special focus on track based alignment due to its enormous complexity and numerical challenges. Presented at Vertex06 – 15th International Workshop On Verte...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید