نتایج جستجو برای: plasma extraction

تعداد نتایج: 515224  

2016
Mahboubeh Rezazadeh Jaber Emami

High-performance liquid chromatography (HPLC) methods employing ultraviolet (UV) detector are not sufficiently sensitive to measure the low plasma concentrations following single oral dose of imipramine. Therefore, in the present study a simple, rapid and yet sensitive HPLC method with UV detection was developed and validated for quantitation of imipramine in human plasma samples. An efficient ...

Journal: :The Journal of endocrinology 1997
F Cumin H P Baum N Levens

This study was performed to test the hypothesis that the kidneys play a primary role in the clearance of endogenous leptin from the circulation. Lean male Sprague-Dawley rats were anesthetized and subjected to various surgical manipulations of the kidneys. Sixty minutes after surgery arterial blood samples were taken at 1-h intervals for up to 8 h. Plasma leptin levels were determined by radioi...

In previous studies, mebudipine, a dihydropyridine calcium channel blocker, showed a considerable potential to be used in cardiovascular diseases. The aim of the current study was to develop a valid method using reversed-phase high performance liquid chromatography coupled with electrospray ionization mass spectrometry to assay mebudipine in the human plasma. Separation was achieved on a Zorbax...

Journal: :iranian journal of pharmaceutical research 0
hoda lavasani biopharmaceutics and pharmacokinetic division, department of pharmaceutics, faculty of pharmacy, tehran university of medical sciences, tehran, iran mario giorgi department of veterinary clinics, faculty of veterinary medicine, university of pisa, via livornese (lato monte) 1, san piero a grado 56010 pisa, italy behjat sheikholeslami biopharmaceutics and pharmacokinetic division, department of pharmaceutics, faculty of pharmacy, tehran university of medical sciences, tehran, iran mohammadhasan hedayati chemical and petroleum engineering department, sharif university of technology. mohammad-reza rouini tehran u of medical sciences

a rapid and sensitive hplc method has been developed for the quantification of mirtazapine (mrz), a noradrenergic and specific serotonergic inhibitor antidepressant (nassa) and its two major metabolites n-desmethylmirtazapine (ndm) and 8-hydroxymirtazapine (8-ohm) in human plasma. the separation was achieved using chromolith c18 column and a mobile phase of acetonitrile: phosphate buffer (ph=3,...

2007
Raymond Naxing Xu Grace E. Kim Brian Boyd Jill Polzin Matthew J. Rieser

Please direct correspondence to Raymond Xu at [email protected] oday, due to its inherent specificity and sensitivity, the most prevalent bioanalytical technique in drug development is liquid chromatography tandem mass spectrometry (LC–MS-MS). This technique is regarded widely as the preferred tool for quantitative determination of drug and metabolites from biological matrices including pla...

2015
Yukihiro Hirao Toshihisa Koga Noriyuki Koyama Yoshihiko Shimokawa Ken Umehara

Sensitive and selective liquid chromatography-tandem mass spectrometry methods have been developed and validated for the determination of delamanid in mouse plasma and lung. Sample preparation involved liquid-liquid extraction with diethyl ether for plasma, or protein precipitation followed by liquid-liquid extraction with tert-butyl methyl ether for lung homogenate. Chromatographic separation ...

2016
Darshan V. Chaudhary Daxesh P. Patel Priyanka A. Shah Jaivik V. Shah Mallika Sanyal Pranav S. Shrivastav

An improved and reliable ultra-performance liquid chromatography/tandem mass spectrometry (UPLC-MS/MS) method has been developed and validated for the determination of lercanidipine in human plasma. Plasma samples with lercanidipine-d3 as an internal standard (IS) were prepared by solid phase extraction on Phenomenex Strata-X cartridges using 100 µL of human plasma. Chromatographic analysis was...

2005
Mohsen Amini Mahnaz Khanavi Abbas Shafiee

A rapid, simple and sensitive high-performance liquid chromatography method was developed for determination of ciprofloxacin in plasma by means of ultraviolet detection. Ofloxacin was used as an internal standard and separation carried on a Novapak C18 column using a mobile phase of 0.01 M phosphate buffer (pH =2.6): methanol (82:18 v/v). Extraction of drug was performed from plasma by liquid-l...

Journal: :Clinical chemistry 1989
C Poiesi A Rodella G Mantero G Cannella R Ferrari A Albertini

We describe a radioimmunoassay (RIA) for measurement of atrial natriuretic peptide (ANP), based on one-step incubation and a simplified extraction procedure. The extraction was performed on a "Supelclean LC 18" column, with 2-mL plasma samples. Use of a diiodinated tracer improved the sensitivity of the RIA method. The minimal detectable value was 5 ng/L. Simplification of the extraction proced...

Journal: :Journal of Veterinary Medical Science 1992

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید