نتایج جستجو برای: photon field size

تعداد نتایج: 1356235  

2005
Wen C. Hsi Yunkai Zhang Michael C. Kirk Damian Bernard James C.H. Chu

The Varian 120 multileaf collimator (MLC) has a leaf thickness of 5 mm projected at the isocenter plane and can deliver a radiation beam of large field size (up to 30 cm) to be used in intensity-modulated radiotherapy (IMRT). Often the dose must be delivered to depths greater than 20 cm. Therefore, during the commissioning of the BrainSCAN v5.21 or any radiation treatment-planning (RTP) systems...

A. Qadir, M. Afzal, M.N. Anjum,

Background: The dosimetric performance of Eclipse 6.5 three dimensional treatment planning system (3DTPS) is evaluated by comparing the calculated and measured dose in two dimensions following the guide lines of American Association for Physicists in Medicine Task Group 53. Materials and Methods: The calculations were performed by the 3DTPS for symmetric as well as asymmetric fields for standar...

A. Eskandarlo, H. Gholam-hosseinian, K. Ghazi-khanlou Sani, M. Mohammadi,

Background: In conventional radiation therapy, regarding normal tissue tolerance, the treatment of bulk tumors is one of the remaining challenges. Grid Radiation Therapy (GRT) is a technique to deliver high doses, approximately 15 – 20 Gy per fraction, to several small volumes located in a large radiation field. This can be performed using a grid block. The current work has concentrate...

2016
Kirill Tuchin

We calculate the photon pair production rate in a strong magnetic field created in off-central heavy-ion collisions. Photon decay leads to depletion of the photon yield by a few percent at RHIC and by as much as 20% at the LHC. It also generates a substantial azimuthal asymmetry (“elliptic flow”) of the final photon distribution. We estimate v2 ≈ 2% at RHIC and v2 ≈ 14% at LHC. Photon decay mea...

2016
Cristi D. Guevara Stephen P. Shipman

In the exciton-polariton system, a linear dispersive photon field is coupled to a nonlinear exciton field. Short-time analysis of the lossless system shows that, when the photon field is excited, the time required for that field to exhibit nonlinear effects is longer than the time required for the nonlinear Schrödinger equation, in which the photon field itself is nonlinear. Mathematics Subject...

2006
P. R. Eastham P. B. Littlewood

We consider polariton condensation in a generalized Dicke model, describing a single-mode cavity containing quantum dots, and extend our previous mean-field theory to allow for finite-size fluctuations. Within the fluctuation-dominated regime the correlation functions differ from their trivial mean-field values. We argue that the low-energy physics of the model, which determines the photon stat...

2005
Yunkai Zhang Wen C. Hsi James C.H. Chu Damian B. Bernard Ross A. Abrams

The effect of gantry rotation on beam profiles of photon and electron beams is an important issue in quality assurance for radiotherapy. To address variations in the profiles of photon and electron beams at different gantry angles, a Dynamic Phantom scanner composed of a 20 x 12 x 6 cm3 scanning Lucite block was designed as a cross-beam-profile scanner. To our knowledge, differences between sca...

Journal: :journal of biomedical physics and engineering 0
f seif arak university of medical sciences m r bayatiani arak university of medical sciences

background: megavoltage beams used in radiotherapy are contaminated with secondary electrons. different parts of linac head and air above patient act as a source of this contamination. this contamination can increase damage to skin and subcutaneous tissue during radiotherapy.  monte carlo simulation is an accurate method for dose calculation in medical dosimetry and has an important role in opt...

Journal: :iranian journal of medical physics 0
asghar mesbahi department ofmedical physics, medical school, tabriz university of medical sciences,,tabriz, iran. 2- department ofradiation oncology, imam hospital, tabriz, iran. ismail zergoug 3-department of radiotherapy, emir abdelkaderanti-cancer center, oran, algeria

introduction radiotherapy with small fields is used widely in newly developed techniques. additionally, dose calculation accuracy of treatment planning systems in small fields plays a crucial role in treatment outcome. in the present study, dose calculation accuracy of two commercial treatment planning systems was evaluated against monte carlo method. materials and methods siemens once or linea...

Journal: :Physical Review A 2007

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید